RS-232C external control

By connecting a computer to the RS-232C terminal, you can control the projector. Use a reverse connection cable as the RS-
232C connection cable.
The commands to control the projector and the response data against the received commands are explained here.
For further information, please consult the dealer where you purchased your projector or consult the Service Center.

1. Communication Specifications

The communication specifications are as follows:

* Factory set value. To change the value, refer to “Setting and Adjusting Other Functions (OPTIONS)” on page 52.

2. Command Format

2-1. Command data format (from the computer to the projector)

When sending a control command, use the following data format.

Header: Designates the head of data and the kind of data.

“!” (21h): Control command to the projector
“?” (2Fh): Query to the projector (Asking command)

ID:

“1” (fixed)

SP:

Designates the delimiter for ID, Command, and Parameter. (20h)

CR:

Designates the terminal of the data. (0Dh)

* [ ] is not necessary when Asking command.

2-2. Response data format (from the projector to the computer)

Upon executing the received control command, the projector sends back the following response data to the computer.

Header: Designates the head of data.

“@” (40h): Fetches data from the projector.

ID:

“1” (fixed)

SP:

Designates the delimiter for ID, Command, and Parameter (20h)

Normal Termination Status: “0” (30h)
CR:

Designates the terminal of the data (0Dh)

Baud rate

9600bps / 19200bps*

Data length

8 bits

Parity

None

Stop bit

1 bit

Flow control

None

Header

ID

SP

Command

SP

Parameter

CR

Header

ID

SP

Normal Termination Status

SP

Parameter

CR

[

]

71

RS-232C external control

ENGLISH

DEUTSH

FRAN

Ç

AIS

ITALIANO

ESPA

Ñ

OL

2-3 Parameters used for the data format

The following three kinds of parameters are prepared for the control command and response data.

(1) Numeric value

Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.
Designation allowable range: “8000” to “7FFF”

(2) ON/OFF

Designates the status (ON/OFF) of the projector, such as POWER and HIDE.

(3) Special parameters

Input switching parameters:

Operation mode parameters:

3. Control command table

The control commands that can be sent from the computer are as follows:

* Keystone: Numeric value can range from “FF80” to “0080”
* Operation mode: Only Asking command is possible

Character

Hex.

Meaning

“0”

30

OFF

“1”

31

ON

Character

Hex.

Meaning

“0”

30

Y/C

“1”

31

VIDEO

“2”

32

PC1

“3”

33

PC2

Character

Hex.

Meaning

“0000”

30h, 30h, 30h, 30h

Stand-by mode

“0001”

30h, 30h, 30h, 31h

Power-on mode

“0002”

30h, 30h, 30h, 32h

Cool-down mode

“0004”

30h, 30h, 30h, 34h

Warning mode

Function

Command

Asking

Kind of data

Power ON

ELSE

Numeric Value

ON/OFF

Special Data

OPERATE

U0F

HIDE

U00

Right Left rev.

U17

Top Bottom inv.

U18

Keystone

U40

Input

U1A

Y/C, VIDEO, PC1, PC2

Operation mode

Z03

Stand-by, Power-on,