Chapter 5

Multiple Zone

Kilns

Note: See also Multiple Zone Options, page 21.

An Overview of Multiple Zone Firing

If you are not sure how many zones your kiln has, look into

the firing chamber. The number of thermocouple tips indi-

cates the number of zones.

In single-zone kilns, the Sentry measures temperature

from one location. When the controller turns on the heat, all

the elements turn on.

With two and three zone kilns, the Sentry measures tem-

perature from each individual zone. It then adjusts the heat

separately for each zone to improve temperature uniformity.

To maintain even temperature, the Sentry calculates not

only temperature difference between zones, but also length

of time needed to change temperature. By carefully timing

heat output, it maintains even temperature with a minimal

loss in firing speed.

Note: Multiple zone kilns use the same Cone-Fire

and Ramp-Hold programming instructions as sin-

gle zone kilns.
Note: Firing a Ramp-Hold program at FULL rate

(1799°F/999°C or higher rate) shuts off multi-

ple-zone control for that firing. The kiln then fires

as a single zone kiln.

Viewing Zone Temperatures

The temperature displayed during firing is an average

taken from all zones. Through the Options key, you can gain

more precise temperature readings:
Zone Difference (DIFF)

1 Press OPTIONS repeatedly until

DIFF

appears.

2 Press ENTER.
3 The maximum difference in temperature between

the zones is shown. (Example:

-005

.)

Zone Temperatures (T123)

1 Press OPTIONS repeatedly until

T123

appears.

2 Press ENTER.
3 The temperature for each zone will display one after

the other. This information will cycle for one min-

ute. Then normal temperature display will return.

For example:

Top zone:

TC 1¯ 1250

Middle zone:

TC 2- 1251

Bottom zone:

TC 3_ 1249

Two Zone Kilns: Adjust Heat in

Center Section (CAdJ)

The Center Adjust option is accessed with the Options

key. It appears only on 2 zone kilns that contain 3 relays and 3

banks of elements. It does not appear on 2 zone kilns with 2

relays, or on 3 zone kilns.

The Center Adjust acts as an infinite control switch that

adjusts heat to the center section of the kiln. A number will

display. 100 is the factory default, meaning 100% heat. You

can change the setting from 0 to 200. The higher the num-

ber, the more the heat in the center section.

1 From

IdLE

, press OPTIONS repeatedly until

CAdJ

appears.

2 Press ENTER. Use any number key to change the

number that appears.

3 Press ENTER. Press STOP to return to

IdLE

.

Thermocouple Failure

In a Multiple Zone Kiln

In a multiple zone kiln, if a thermocouple fails, the firing

will continue as a single-zone kiln so long as one thermocou-

ple still operates.

FAIL

will appear, alternating with the

thermocouple that failed (i.e.

TC 1¯

).

Power Output Lights

The 3 lights to the right of the

temperature display turn on

when the controller sends power

to the relays.

Two Zone Kiln The top light shows power to the relay

for the top section of the kiln. The bottom light shows

power to the bottom. Ignore the center light.

Three Zone Kiln The top light indicates power to the

top section relay, the middle light to the middle section, and

the bottom light to the bottom.

Testing Multiple Zone Elements

When relays or thermocouples are connected to the

wrong controller terminals, zones will show a wide tempera-

ture difference. To wire the kiln properly, trace the switch

box wiring with the kiln’s wiring diagram. Also, see “Ele-

ment Test,” page 21.

16