Appendix b, Low fire cones °f, Medium fire cones °f – Sentry Industries Sentry 2.0 User Manual

Page 26: High fire cones °f

Advertising
background image

26

Appendix B: Preset Standard

Cone-Fire Schedules - °F

These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your

changes. Then load your new schedule into Ramp-Hold.

Low Fire Cones °F

Segment 1

Segment 2

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

022

396

979

108

1087

021

396

1004

108

1112

020

396

1051

108

1159

019

396

1144

108

1252

018

396

1211

108

1319

017

396

1252

108

1360

016

396

1314

108

1422

015

396

1348

108

1456

014

396

1377

108

1485

013

396

1431

108

1539

012

396

1474

108

1582

011

396

1499

108

1607

Medium Fire Cones °F

Segment 1

Segment 2

Segment 3

Segment 4

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

Rate 3 Temp. 3

Rate 4 Temp. 4

010

324

1022

153

1112

180

1549

108

1657

09

324

1022

153

1112

180

1580

108

1688

08

324

1022

153

1112

180

1620

108

1728

07

324

1022

153

1112

180

1681

108

1789

06

324

1022

153

1112

180

1720

108

1828

05

324

1022

153

1112

180

1780

108

1888

04

324

1022

153

1112

180

1837

108

1945

03

324

1022

153

1112

180

1879

108

1987

02

324

1022

153

1112

180

1908

108

2016

01

324

1022

153

1112

180

1938

108

2046

High Fire Cones °F

Segment 1

Segment 2

Segment 3

Segment 4

Cone

Rate 1 Temp. 1

Rate 2 Temp. 2

Rate 3 Temp. 3

Rate 4 Temp. 4

1

324

1022

153

1112

162

1863

108

2079

2

324

1022

153

1112

162

1872

108

2088

3

324

1022

153

1112

162

1890

108

2106

4

324

1022

153

1112

162

1908

108

2124

5

324

1022

153

1112

162

1951

108

2167

6

324

1022

153

1112

162

2016

108

2232

7

324

1022

153

1112

162

2046

108

2262

8

324

1022

153

1112

162

2064

108

2280

9

324

1022

153

1112

162

2084

108

2300

10

324

1022

153

1112

162

2129

108

2345

Advertising