Connection with rs-485 – Samsung SIR-S4120R User Manual

Page 13

Advertising
background image

2-6

2-5

DIGITAL VIDEO RECORDER

Connection with RS-485

If you control cameras, remote control is allowed through connection with RS-485 (up to

1.2km).

A. Communication method

Data transmission method: Start-Stop Asynchronized Serial Interface

Protocol: 8 bit Data, 1 Stop bit, None Parity

Transmission speed: 4800, 9600, 19200, 38400, 115200 bps

B. RS-485 terminal and Pin specifications

C. Data Format (Samsung Protocol)

DATA +
DATA -

9 Byte Fixed

( ) : Byte numbers

Start Code (A0H)

(1)

Data Byte

Type

Contents

Remarks

Byte 1

Start Code

0xA0

Start of Data Packet

Byte 2

Sender Addr.

Transmission Address

Source Range (0x00 ~ 0xFF)

Byte 3

Target Addr.

Reception Address

Destination Range (0x00 ~ 0xFF)

Byte 4

Only Image Recorder Command

0x0A

Byte 5

Key Function

Range (0x01 ~ 0xFF)

Byte 6

Command

0xFF

0xFF

Byte 7

0xFF

0xFF

Byte 8

0xFF

0xFF

Byte 9

Check Sum Lower byte of (0xFFFF - (values adding Byte 2 ~ Byte 8))

Start Addr.

(1)

Target Addr.

(1)

Command

(5)

Check Sum

(1)

D. Code value by key

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6, 7, 8

Byte 9

Response

(Byte 5)

RECORD

0xA0

Src.Addr

Dest.Addr.

0x1A

0x0B

0xFF

Check Sum

Byte 5

REC LOCK

0xA0

Src.Addr

Dest.Addr.

0x1A

0x0A

0xFF

Check Sum

Byte 5

VCR

0xA0

Src.Addr

Dest.Addr.

0x1A

0x3D

0xFF

Check Sum

Byte 5

SEARCH

0xA0

Src.Addr

Dest.Addr.

0x1A

0x02

0xFF

Check Sum

Byte 5

MENU

0xA0

Src.Addr

Dest.Addr.

0x1A

0x01

0xFF

Check Sum

Byte 5

ENTER

0xA0

Src.Addr

Dest.Addr.

0x1A

0x35

0xFF

Check Sum

Byte 5

LEFT

0xA0

Src.Addr

Dest.Addr.

0x1A

0x06

0xFF

Check Sum

Byte 5

RIGHT

0xA0

Src.Addr

Dest.Addr.

0x1A

0x07

0xFF

Check Sum

Byte 5

STOP

0xA0

Src.Addr

Dest.Addr.

0x1A

0x08

0xFF

Check Sum

Byte 5

RIGHT

0xA0

Src.Addr

Dest.Addr.

0x1A

0x09

0xFF

Check Sum

Byte 5

UP

0xA0

Src.Addr

Dest.Addr.

0x1A

0x04

0xFF

Check Sum

Byte 5

DOWN

0xA0

Src.Addr

Dest.Addr.

0x1A

0x05

0xFF

Check Sum

Byte 5

EJECT

0xA0

Src.Addr

Dest.Addr.

0x1A

0x3E

0xFF

Check Sum

Byte 5

E. Others

Above data format and transmission speed may be changed depending on future
development conditions.

PC operates as Master, and Target Set as Slave in transmission/reception of data.

No status other than Set Key Function should be received.
(Some delay can be happen due to communication speed).

DATA -
DATA +

[SET COMMAND]