A

10% tolerance is permissible during initial start of the

spindle but must return to

±

5% before reaching 7,200 RPM.

The

±

5% must be maintained after the drive signifies that its

power-up sequence has been completed and that the drive
is able to accept selection by the host initiator.

3

See the

+

12V current profile in the

Product Manual .

4

This condition occurs when the Motor Start option is en-
abled and the drive has not yet received a start motor
command.

5

See “Conducted noise immunity” in the

Product Manual.

The specified voltage tolerance is inclusive of ripple, noise,
and transient response.

6

At power-up, the motor current regulator limits the

+

12V

current to an average value of less than 2.0A, although
instantaneous peaks may exceed this value. These peaks
should measure 5 msec duration or less.

7

Minimum current loading for each supply voltage is not less
than 7% of the maximum operating current shown.

8

Use separate ground returns for

+

5 and

+

12V supplies.

9

Where power is provided to multiple drives from a common
supply, carefully consider individual-drive power require-
ments. Where multiple units are powered on simultaneously,
be sure the peak starting current is available to each device.

10

Operating condition is a third-stroke seek at OD and read
one track. The command is issued every 0.07 seconds.