S

ERVICE

S

TRATO

S

TEAM

EZ

C

OUNTERTOP

S

TEAMER

P

AGE

18

OF

56 O

WNER

S

M

ANUAL

1189953

(10/08)

S

ERVICE

WARNING

ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS
EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING
EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR
RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY
PARTS.

NOTICE

INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS
EQUIPMENT.

A serial plate is located on the right side of the steamer, near the top right corner. A second serial plate is located on
the rear of the steamer near the top left corner (see Figure 1).

Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized
Parts Distributor or a Southbend Authorized Service Agency.

When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.

This section contains troubleshooting flowcharts, procedures, and electric schematics to assist a qualified service
technician in the servicing of a StratoSteam countertop steamer.

A description of how the steamer operates appears on the next page.

To remove a side panel (for access to the interior), remove the securing screw near the center of the bottom edge of
the panel. To remove the top panel, remove the two securing screws on the rear face, then slide the top panel forward
and off.

The door is field-reversible (contact Southbend for instructions).

T

ROUBLESHOOTING

F

LOWCHARTS

,

P

ROCEDURES

,

AND

W

IRING

D

IAGRAMS

Find the symptom below that corresponds to the malfunction, then turn to the corresponding page. Follow the
flowchart on that page until the problem is solved.

Troubleshooting Flowchart, Procedure, or Wiring Diagram

Page

Troubleshooting Flowchart: Steamer Not Heating Up, “Power” Light Is Not Lit

21

Troubleshooting Flowchart: Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit

22

Troubleshooting Flowchart: Buzzer Does Not Come On When Timer Runs Out

23

Troubleshooting Procedure: Heating Cartridge Check (at Contactor)

24

Troubleshooting Procedure: Power Switch Check

25

Troubleshooting Procedure: Contactor Check

26

Troubleshooting Procedure: Timer and Buzzer Check

27

Troubleshooting Procedure: Door Switch Check

28

Troubleshooting Procedure: High Limit Thermostats Check

29

Troubleshooting Procedure: Water-Level-Control Sensor Check

30

Troubleshooting Procedure: Water Solenoid Check

31

Troubleshooting Procedure: Pressure Switch Check

32

Wiring Diagram for 208/220/240 Volt Units Built on or After September 1, 2008

33

Wiring Diagram for 208/220/240 Volt Units Built before September 1, 2008

34

Wiring Diagram for 480 Volt Units Built on or After September 1, 2008

35

Wiring Diagram for 480 Volt Units Built Before September 1, 2008

36

Advertising