Troubleshooting

Troubleshooting

Error checklist

If still operating problems with your transmission installation occur, please contact your local Sennhe-
iser agent for assistance.

Problem

Possible cause

Possible solution

No operation
indication

Batteries are flat or rechargeable
battery is flat

Replace the batteries or recharge the
accupack

No audio signal

Transmitter and receiver are not on the
same frequency.

Set transmitter and receiver to the
same frequency .

The transmitter is out of range.

Reduce the distance between
transmitter and receiver.

RF signal available,
but no audio signal

The transmitter’s microphone is muted
(“MUTE”)

Deactivate the muting function

Defective microphone

Replace microphone

Defective headphones

Replace headphones

Audio signal has a
high level of
background noise

Transmitter sensitivity is adjusted too
low

see “Adjusting the sensitivity” on
page 47

Audio signal is
distorted

Transmitter sensitivity is adjusted too
high

see “Adjusting the sensitivity” on
page 47

L 2015:
red LED flashes
besides a charging
compartment

No contact with the rechargeable
battery (contacts are dirty or
rechargeable battery is not inserted
correctly)

Clean the contacts or insert the
rechargeable battery correctly

rechargeable battery is defective
(overaged or defective rechargeable
battery cells)

Replace the accupack

rechargeable battery temperature is
too low or too high

Always charge the rechargeable
battery at room temperature

Batteries (primary cells) or individual
rechargeable batteries have been
inserted

Only charge the BA 2015 accupack!