“Service Request” Light Comes On During Operation

DISCONNECT POWER AT CIRCUIT BREAKER.

“Service Request” light comes on during operation.

Is water level

at or above normal level

in cavity?

Yes

No

Check for adequate water pressure to unit.

DISCONNECT POWER AT CIRCUIT BREAKER.

Remove control panel, but leave plugged in.

Leave all wires connected to R1 relay, but pull back

connectors enough to allow meter-probe access.

DISCONNECT POWER AT CIRCUIT BREAKER.

Turn unit off and check that unit drains fully.

Open door. Turn unit back on and wait 30 minutes.

Yes

No

Does water

level exceed normal

level?

Disconnect water inlet assembly at

compression fitting.

Attach pressure gauge to copper tube and check

pressure downstream of regulator.

Shut water off as close to steamer as possible.

Remove rear cover from unit.

Disconnect water supply.

Check float valve (see

Figure 16 on page 33).

Clean or replace as

necessary.

Adjust or replace

pressure regulator.

Yes

No

Pressure above

3 psig?

Replace solenoid valve.

Yes

No

Reconnect power to unit. WAIT 9 MINUTES.

Is resistance

over 1000 ohms?

Check voltage across R1 coil (where wires B42 and

B70 are connected).

Does voltage

match serial plate

voltage?

Check float switch and

replace as necessary

(see Figure 14 on page

31).

Yes

No

Shut off water supply as close to steamer as possible.

Remove screen from strainer and clean or replace as necessary. Reassemble, reconnect, and

recheck the steamer. If the Service Request light still comes on, examine the following for obstructions

or deposits: pressure regulator, solenoid, and float valve. Clean or replace as necessary.

Check resistance between terminal block position 1

and NO terminal on R1 relay (where wire B72 is

connected).

Check voltage between NO and C

terminals on R1 relay (where wires

B72 and B71 are connected).

Does voltage

match serial plate

voltage?

Yes

No

Replace R1 relay
(part # 1181545).

Check high-limit

thermostats (see Figure

18 on page 35) and

replace as necessary.