Heating Element Resistance Check (at Contactor)

B

A

Contactor
(top view)

C

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove control panel.

3. DO NOT REMOVE HEATING ELEMENT LEAD WIRES FOR THIS TEST.

4. Place test leads between terminals A and C on left side of contactor.

5. Check the resistance and compare to the allowable range in the following table:

Model SEZ-3

Model SEZ-5

Allowable Resistance (Ohms)

Allowable Resistance (Ohms)

Three-Phase

Single-Phase

Three-Phase

Single-Phase

Voltage

A-B or B-C

A-C

A-C

A-B or B-C

A-C

A-C

208

10 to 12

14 to 16

5 to 6

8 to 10

11 to 13

4 to 5

220

12 to 13

15 to 18

6 to 7

9 to 11

13 to 15

5 to 6

240

14 to 16

18 to 21

7 to 9

11 to 13

15 to 17

6 to 7

480

55 to 64

73 to 85

29 to 34

45 to 52

60 to 70

24 to 28

6. For three-phase units, check resistance between terminals A and B and between terminals B and

C similarly.