Roubleshooting – Southbend SEZ-5 User Manual

Page 29

Advertising
background image

SEZ S

ERIES

C

OUNTERTOP

S

TEAMERS

T

ROUBLESHOOTING

O

PERATOR

S

M

ANUAL

1181587

P

AGE

29

TROU

BLE

S

H

OOTI

N

G

Figure 12

Timer and Buzzer Check

Buzzer

Timer

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove control panel.

3. Set timer for one minute and allow to time out. If timer does not run, then replace.

4. Remove buzzer lead wires from timer and terminal block position 6.

5. Place test leads between positions 1 and 3 on the timer.

6. Check for continuity. If no continuity, replace timer.

7. Place test leads in terminals of buzzer lead wires.

8. Check that resistance is approximately 3.4 Kohms. Otherwise, replace buzzer.

Advertising