Sanyo MPX-MD162 User Manual

Page 30

Advertising
background image

VCR SETTING AND EXTERNAL CONTROL
COMMUNICATION SPEED SETTING

Menu 3

(VCR SET)

You must set this unit output to match the type (Timelapse or
Real time VCR) and settings of the VCR used for recording.

Setting the VCR Output

1

Press the MENU button 3 times to display the (VCR
SET) menu.

2

Using the + (or –) button, select the desired “VCR
MODE” setting, then press the

l

button.

Following this procedure, select the settings for REC
SPEED
, ALARM REC SPEED, PROGRAM REC MODE
and COLOR KILLER.

3

Press the

l

button to go to the (SERIAL SET) menu,

or

Press the MENU button to go to the next menu
screen, or

Press the EXIT button to exit the menu display.

VCR SET menu

If the VCR is not Equipped with a SW (switching) Output
Connector

VCR MODE

TLS:

If using a timelapse VCR. (Default setting)

REAL: If using a real time VCR.

REC SPEED

The recording speed settings on this unit correspond to
recording durations on a T-120 tape.
With a timelapse VCR
Set the recording speed to match the recording speed of the
timelapse VCR.
The available speeds are: 2 (2H) (Default setting), 12 (12H),
24 (24H), 48 (48H), 72 (72H), 96 (96H), 120, 168, 240, 360, 480,
720, 960 (960H)
With a real time VCR
Set the recording speed to match the recording speed of the real
time VCR.
The available speeds are: 6 (6H) (Default setting), 18 (18H),
30 (30H), 48 (48H), 72 (72H), 96 (96H), 120, 168, 240, 360 ,
480, 720, 960 (960H)

NOTE: Real time VCRs speed is based on a T-160 cassette

tape. When setting this unit to 6H, 18H or 30H, refer to
the table 1 for the speed correspondence, and select
the speed on the VCR accordingly.

Table 1

REC SPEED setting

Recording speed setting on the

real time VCR

6 (6H)

8H (8-hour mode)

18 (18H)

24H (24-hour mode)

30 (30H)

40H (40-hour mode)

ALARM REC SPEED

With a timelapse VCR

Set the recording speed to use when an alarm trigger is received to
match the alarm recording speed of the timelapse VCR.
The available speeds are:

2 (2H) (Default setting), 12 (12H), 24 (24H), NC, F2

NC:

When an alarm trigger is received, the recording speed is not
changed and stays as set under “REC SPEED”.

F2:

Use this setting when using the SW output terminal on a timelapse
VCR that does not output a switching signal in 2H mode.

With a real time VCR
Set the recording speed to use when an alarm trigger is received to
match the alarm recording speed of the real time VCR.
The available speeds are:

6 (6H) (Default setting), 18 (18H), NC, F6

NC: When an alarm trigger is received, the recording speed is

not changed and stays as set under “REC SPEED”.

F6: Use this setting when using the SW output terminal on a real

time VCR that does not output a switching signal in 6H mode.

PROGRAM REC MODE

Using the programmed recording mode you can decided to only
output the recorded live pictures from a certain camera or to give
priority to the pictures from a certain camera.
This will set the programmed recording mode.
MODE1:

Only the live pictures from the camera for which programmed
recording is set are recorded.

MODE2:

The live pictures from the camera for which programmed
recording is set are recorded together with the live pictures
from the other cameras.

OFF:

Programmed recording will not be done. (Default setting)

NOTE:

Programmed recording of multiple cameras is done by switching to
each camera in order.

In the (CAMERA SET) menu, set for each camera if programmed
recording is to be conducted or not (see page 36).

The recording mode set here is the same as the ACTIVE REC
recording mode (see page 34). The programmed recording mode is
the normal recording mode applied to the camera, while the active
recording mode will modify the recording mode for the camera when
an external alarm or a video sensor trigger is received.

Any camera for which programmed recording is turned off, will not be
recorded when an external alarm or a video sensor trigger is
received. To record from a camera for which programmed recording
is turned off, when an external alarm or a video sensor trigger is
received, set the active recording mode to on.

COLOR KILLER

(Default setting: OFF)

Used to playback a tape recorded through a black and white
multiplexer, using a color multiplexer.
ON:

When using a black and white tape, the color killer function is active.

OFF:

The color killer function is not active.

NOTE: Model MPX-MD162 does not have COLOR KILLER.

2

(Timelapse VCR)

(Real time VCR)

(VCR SET)
VCR MODE TLS
REC SPEED 2 H
ALARM REC SPEED 2 H
PROGRAM REC MODE OFF
COLOR KILLER OFF
VIDEO LOSS ON
DATA ON
DISPLAY FREEZE
<RS232C SET>

DATA SPEED

19200

(VCR SET)
VCR MODE REAL
REC SPEED 6 H
ALARM REC SPEED 6 H
PROGRAM REC MODE OFF
COLOR KILLER OFF
VIDEO LOSS ON
DATA ON
DISPLAY FREEZE
<RS232C SET>

DATA SPEED

19200

L8FC5/US (MPX-CD162, MD162 GB) 2000. 8. 31