Alarm and sensor setting, Menu 4 (alarm set), Changing the settings – Sanyo MPX-MD162 User Manual

Page 32: Alarm set menu duration, Retrigger, Buzzer, Data, Mon.1 out, Mon.2 out

Advertising
background image

ALARM AND SENSOR SETTING

Menu 4

(ALARM SET)

When an alarm trigger is received from sensors such as a door
bell, movement sensor, etc. you can set the display mode and
the recording mode for the pictures from the concerned camera.
Using the (SENSOR SET) settings (see page 32), the triggers
received from the video sensors can be set to operate as alarm
triggers.

Changing the Settings

1

Press the MENU button 4 times to display the (ALARM
SET) menu.

2

Using the + (or –) button, select the desired setting,
then press the

l

button.

Repeat step 2, until all the settings are as desired.

3

Press the

l

button to go to the (SENSOR SET)

menu, or

Press the MENU button to go to the next menu
screen, or

Press the EXIT button to exit the menu display.

ALARM SET menu

DURATION

(Default setting: 10 S)

The available durations are (seconds):

1, 2, 3, 4, 5, 10, 20 (in 10 seconds increments)... 180,
CC, NC, INDIV., OFF

CC:

The alarm will go on as long as the alarm signal is
received (minimum 1 second).

NC:

The alarm will continue until reset.

INDIV.: The alarm duration will be as set for each of the cameras.
OFF:

No alarm duration setting.

NOTE: If the “INDIV.” setting is used, in the (CAMERA SET)

menu, enter the desired alarm duration for each
camera (see page 38).

RETRIGGER

(Default setting: OFF)

To set if an alarm is received while the unit is already in alarm
mode.
ON: During alarm mode, other alarm triggers will be received

and the alarm duration will be extended.

OFF: The unit will not receive another alarm, while one is

already being received.

BUZZER

(Default setting: ON)

ON: A buzzer will be heard when an alarm trigger is received.
OFF: The buzzer will not be heard.

DATA

(Default setting: ON)

ON: The alarm data is recorded.
OFF: The alarm data is not recorded.

MON.1 OUT

(A) FULL (Default setting):

If an alarm trigger is received, the picture from the camera
corresponding to the alarm input will be displayed full
screen.

DOUBLE ALARM (Default setting: LAST)

When using the “FULL” setting at the “MON.1 OUT
line, the following settings are possible.
LAST: When triggers from multiple cameras are
received in full screen mode, the picture from the
camera of the last alarm received is displayed.

FIRST: When triggers from multiple cameras are
received in full screen mode, the picture from the
camera of the first alarm received only is displayed.
Camera pictures from subsequent alarm triggers will
not be displayed.
SWITCH: When triggers from multiple cameras are
received in full screen mode, the picture from each
concerned camera will be displayed sequentially at 1
second interval.

(B) MULTI16: When an alarm trigger is received, the display

will switch to a 16 divisions screen.

(C) MULTI9: When an alarm trigger is received, the display

will switch to a 9 divisions screen. However, if
the alarm trigger is at a camera other that the
ones displayed in 9 divisions screen, the picture
from the concerned camera is not displayed.

(D) NC: The display mode will remain unchanged when an

alarm trigger is received.

MON.2 OUT

(Default setting: OFF)

ON: Monitor 2 display will switch to full screen alarm display,

when an alarm trigger is received.

OFF: Monitor 2 display will not change.

2

(ALARM SET)

DURATION 10 S

RETRIGGER OFF

BUZZER ON

DATA ON

MON.1 OUT FULL

DOUBLE ALARM LAST

MON.2 OUT OFF

(SENSOR SET)

SENSOR ALARM OFF

DURATION 10 S

(CAMERA SET) NO.01

TITLE

--------

01

DAY NIGHT

PROGRAM REC OFF OFF

AL.DURATION 10 S 10 S

MON.MASK OFF OFF

SEQUENCE

1 S

1 S

(A)

(ALARM SET)

DURATION 10 S

RETRIGGER OFF

BUZZER ON

DATA ON

MON.1 OUT FULL

DOUBLE ALARM LAST

MON.2 OUT OFF

(SENSOR SET)

SENSOR ALARM OFF

SENSOR DURATION 10 S

(C)

(ALARM SET)

DURATION 10 S

RETRIGGER OFF

BUZZER ON

DATA ON

MON.1 OUT NC

MON.2 OUT OFF

(SENSOR SET)

SENSOR ALARM OFF

SENSOR DURATION 10 S

(B)

(ALARM SET)

DURATION 10 S

RETRIGGER OFF

BUZZER ON

DATA ON

MON.1 OUT MULTI16

MON.2 OUT OFF

(D)

(ALARM SET)

DURATION 10 S

RETRIGGER OFF

BUZZER ON

DATA ON

MON.1 OUT MULTI9

MON.2 OUT OFF

L8FC5/US (MPX-CD162, MD162 GB) 2000. 8. 31

English

31