NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Operating Options

The rocker switch on your SDVI gas insert is used to turn the burner on

and off while the pilot is on. The rocker switch can be installed in the hole

in the right side of the top surround panel or in the hole in the panel to

the left of the igniter button. The hole in the panel is covered by a label

which must be carefully cut out before installing the rocker switch. The

switch must be disconnected from the coil of wire to which it is attached,

the plastic nut unscrewed from the back side of the switch, and then the

switch can be inserted into the hole at either location. If the switch is to

be located in the surround, route the wire behind the igniter bracket and

through the hole in the lower right side of the insert. Attach the three

plastic adhesive wire restraints (found in the bag in the firebox) to the

side surround panel. Feed the wire through these restraints and up to the

switch. Care should be taken to ensure the wire does not come in contact

with the hot surfaces of the firebox. Reconnect the wires to the switch.

A wall-mounted switch, a millivolt wall thermostat, or a remote control,

can be used to supplement the rocker switch. The gas valve is powered

by millivolts generated by the pilot assembly. This millivolt system is very

sensitive to electrical resistance, therefore, make sure all connections are

tight, clean, and free from corrosion. Do not splice any millivolt wires.

Consult the table on this page to determine the proper gage of wire for

the thermostat or wall switch connections. This table refers to the total

length of the wire (out to the switch and back). The thermostat must

be a millivolt type. A 24-volt furnace thermostat will not work. Never

hook up household current - 120 Volts - to the millivolt system. It is not

recommended to hook up any more than two switches to the insert (for

example a rocker switch and a wall thermostat). Additional switches may

affect the system resistance and increase the chance of the burner not

igniting. Follow the instructions included with the thermostat or remote

control for wiring.

The thermostat, remote control, and rocker switch will turn the burner

on and off independently. Be sure to set the rocker switch to the “OFF”

position when using the thermostat or remote control and set the ther-

mostat or remote control to the lowest temperature when you wish to

use the rocker switch only, otherwise one may override the other. If a

remote thermostat is to be used with the insert, do not place the receiver

under the firebox.

Thermostat Wire

Wire Size

Maximum Length

12 Gage

100 Feet

14 Gage

64 Feet

16 Gage

40 Feet

18 Gage

25 Feet

20 Gage

16 Feet

Millivolt Control System

This fireplace operates on a millivolt control system. As such, no addi-

tional power supply is needed for the fireplace to heat. The pilot assembly

contains a thermocouple, that when heated by the pilot flame, generates

electricity (millivolts- mV=1/1000 of a volt) which opens a valve allow-

ing gas to flow to the pilot assembly. The pilot assembly also contains a

thermopile, that when heated by the pilot flame, generates electricity that

flows to terminal #1 (labeled THTP) on the gas valve. When the electricity

is conducted from terminal #1 through the on/off switch, thermostat,

or receiver of the remote control to terminal #3 (labeled TH) on the gas

valve, the main burner will ignite.

CAUTION: Label all wires prior to disconnection when servic-

ing controls. Wiring errors can cause improper and dangerous

operation.

ATTENTION: Au moment de l'entretien des commandes,

étiquetez tous les fils avant de les débrancher. Des erreurs

de cáblage peuvent entraîner un fonctionnement inadéquat et

dangereux.

Millivolt Control Schematic

Sparker

Pilot Hood

ON/OFF Rocker Switch, Thermo-

stat, or Remote Thermostat

Pilot Assembly

Thermocouple

Piezo Igniter

White

Gas Inlet

Pilot Gas Line

Brown

Figure 18

Thermopile

Wiring Terminals

TH

TP

TH/TP

Advertising