Warning – Superior SDVI User Manual

Page 20

Advertising
background image

20

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

CAUTION: Wear gloves and safety glasses for protection while

doing required maintenance.

Verify proper operation after servicing.

S'assurer que l'appareil fonctionne adéquatement une fois

l'entretien terminé.

Maintenance Checklist

The following should only be performed by a qualified service

technician.

1. Annual inspection should be made and the following checks per-

formed:

o

When unit is cool, remove glass and inspect burner for dirt, soot,

and lint accumulations, and remove if necessary. If excessive soot

accumulation is present on burner, have a qualified service technician

adjust the burner for proper combustion.

o

Clean inside of glass with gas fireplace glass cleaner. NEVER attempt

to remove or clean the glass when the unit is hot.

o

Check the hot air outlet vents for lint or other accumulations. Never

block or restrict vent openings, obstruct flow of ventilation air, or use

vents other than those approved for use with the SDVI gas insert.

o

Check that the chimney and its outlet are open and free of soot, block-

age, or debris.

o

Check gaskets once a year. Gaskets must be tight. Replace if neces-

sary.

o

Inspect the pilot system for proper flame. NEVER ADJUST THE PILOT

until after the gas pressure has been checked and the supply lines have

been completely bled (this may take an hour or more when bleeding

through the pilot). All pilots are checked and burned at the factory

prior to shipment. The pilot adjustment screw is located below the

ON/OFF/PILOT control knob. Remove the pilot adjusting cover with

a flat-bladed screwdriver to access the pilot adjusting screw. Adjust

the pilot screw to properly size the flames. The flames should directly

contact the thermopile and extend across the main burner ports. Be

careful not to back the screw out of its threads. Replace the cover and

check for gas leaks using a gas leak test solution.

o

Check that the area around the insert is kept clear and is free of

combustible materials, gasoline, and other flammable vapors and

liquids.

o

Check the millivolt system as per the table on this page.

2. The viewing glass should be cleaned periodically (see Glass Main-

tenance).

Proper Pilot Flame Appearance

Figure 19

MAINTENANCE AND SERVICING

Millivolt and System Checks

Check

Test

To

Test

Connect

Meter

Leads to

Terminals

Thermostat

Connects

Meter Read-

ing

Should Be

A

Complete

System

2 & 3

Closed

100 MV

or More

B

Thermopile

Output

1 & 2

Open

Greater Than

325 MV

C

System

Resistance

2 & 3

Closed

2.5 Ohms

WARNING

Turn off gas and electrical power to the fireplace

and allow it to cool before cleaning or servicing

the appliance.

Advertising