NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Insert Dimensions

Minimum Fireplace Opening Required

A = 31-1/4” (794mm) Front Opening
B = 17-1/4” (438mm) Height
C = 19” (483mm) Rear Width**
D = 16” (406mm) Fireplace Depth

* Top air duct will need to be removed for short ZC applications. Replace

tap tights when removed.

**This dimension is with the air duct hood removed (see Zero Clearance

Fireplace Installation on Page 11).

Minimum Fireplace Cavity

Top View

Side View

Insert Dimensions

Width of insert behind Surround Panels

31-1/4" (794mm)

Rear height

17-1/4" (438mm)

Insert depth into fireplace

15-3/4" (400mm)

Flue center line from back of surround with 45º collar 13-3/4" (349mm)
Flue collar diameter (OD)

2-15/16" (75mm)

Figure 1

Figure 2

Figure 3

31-1/4”(794mm)

7-1/4”

(184mm)

2-1/2”

(64mm)

15-3/4”

(400mm)

Air Intake

Flue

13”

(330mm)

14-1/2”

(368mm)

16”(406mm)

17-1/4”

(438mm)

7-1/2”

(191mm)

15-1/4”

(387mm)

CAUTIONS

Trim panels or surrounds must not seal ventila-

tion openings in the existing fireplace that the

appliance is installed in.

The fireplace in which this gas insert is to be

installed must be thoroughly cleaned if it has

been used to burn wood or synthetic logs. Have

the chimney and all inside surfaces of the fire-

place brushed and vacuumed so that no soot,

embers, or loose combustion deposits can be

drawn into the heat circulation blower and blown

into the living area.

If any portion of the chimney system shows signs

of structural or mechanical weaknesses, such

as: cracks, leaky joints, corroded or warped

surfaces, the faulty portion must be repaired

or replaced prior to installing this appliance.

The factory built firebox must accept the insert

without modification other than removing bolted

or screwed together pieces such as baffles /

smoke shelf / deflectors, ash lips, glass door,

screen or door tracks, log grates, refractory or

masonry lining and damper assemblies. Any

fireplace component, which is removed, must be

retained so they can be reinstalled to restore the

fireplace to its original operating condition. The

removal of any part must not alter the integrity

of the outer shell of the pre-engineered fireplace

cabinet in any way. Any parts removed must be

replaceable. If any components are removed

from (or altered) from the existing fireplace,

a Warning Label (see Page 5) must be affixed

inside the fireplace firebox, so that it shall be

visible upon removal of the fireplace insert. Note:

RTV high temperature silicone is an approved

adhesive to affix the label.