Superior SDVI User Manual

Page 22

Advertising
background image

22

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Fuel Conversion

Converting your SDVI gas insert between natural gas and LP can be accom-
plished by installing a conversion kit (valve regulator and burner orifice).
Only a qualified service technician should perform the conversion.

Conversion Kit: Please see instructions provided with conver-

sion kit.

Blower Removal

Unplug the power supply cord from the electrical outlet prior to remov-
ing the blower. The blower can be accessed through the back wall of
the firebox.

Remove the insert face, glass door and log set. All of these items are fragile
so handle them with care. Next, remove the nine allen head screws around
the outside of the panel fastened to the back wall of the firebox. Rotate the
top of this panel toward the front, remove the two wires connected to the
blower, and then lift the panel with the blower attached out of the firebox.
To reinstall the blower, repeat these steps in the reverse order.

Figure 21

Blower Wiring Schematic

Green (Ground)

Black (Hot)

From Power Source

Speed Control

White (Neutral)

Black

Blower

White

Blower Snap Switch

Electrical Requirements:

This gas insert operates without an outside power source, however the
blower requires a 120 Volt electrical service outlet. This appliance, when
installed, must be electrically grounded in accordance with local codes,
or in the absence of local codes, the National Electrical Code ANSI/NFPA
70 - latest edition. (See Operating Options for thermostat and ON/OFF
switch information).

CAUTION: Label all wires prior to disconnection when servic-

ing controls. Wiring errors can cause improper and dangerous

operation.

ATTENTION: Au moment de l'entretien des commandes,

étiquetez tous les fils avant de les débrancher. Des erreurs

de cáblage peuvent entraîner un fonctionnement inadéquat

et dangereux.

Advertising