Cutting/extending the piping – Samsung A6 User Manual

Page 36

Advertising
background image

E-

36

I

NSTALLING THE

I

NDOOR

U

NIT

Five metres(16ft 5in) of piping is supplied with the air
conditioner(Optional). This length can if necessary be:

Extended to a maximum of “L” m/ft.
Shortened as required

If more than 5m(16ft 5in) of piping is required:

The assembly cable must also be extended
Refrigerant must be added to the circuit by an

approved installer; otherwise, the indoor unit may
freeze

1

Make sure that you have the required tools available
(pipe cutter, reamer, flaring tool and pipe holder).

2

If you wish to shorten the piping, cut it using a pipe cutter, taking care to
ensure that the cut edge remains at a 90° angle with the side of the pipe,
and referring to the illustrations below for examples of edges cut correctly
and incorrectly.

Oblique

Rough

Burr

3

To prevent any gas from leaking out, remove all burrs at the cut end of the
pipe, using a reamer.

4

Slide a flare nut on to the pipe and modify the flare.

Pipe

Outer Diameter (D)

Depth (A)

Liquid refrigerant

6.35 mm(1/4˝)

1.3 mm(1/16˝)

Gas refrigerant

9.52 mm(3/8˝)

1.8 mm(1/16˝)

Gas refrigerant

12.70 mm(1/2˝)

2.0 mm(1/16˝)

Gas refrigerant

15.88 mm(5/8˝)

2.2 mm(1/8˝)

5

Check that the flaring is correct, referring to the illustrations below for
examples of incorrect flaring.

Inclined

Damaged Surface

Cracked

Uneven Thickness

6

Align the pipes to be connected and tighten the flare nuts first manually
and then with a wrench, applying the following torque.

7

For further details on how to connect up to the outdoor unit and purge the
circuit, refer to page 41.

90

O

O

x

x

x

Cutting/Extending the Piping

Pipe

Outer Diameter

Torque

Liquid refrigerant

6.35 mm(1/4˝)

160kg•cm(11.6ft•lb )

Gas refrigerant

9.52 mm(3/8˝)

300kg•cm(21.8ft•lb )

Gas refrigerant

12.70 mm(1/2˝)

500kg•cm(36.4ft•lb )

Gas refrigerant

15.88 mm(5/8˝)

700kg•cm(50.6ft•lb )