Once you have checked that there are no leaks in the system, you can insulate
the piping, hose and cables and place the indoor unit on the installation plate.

1

To avoid condensation problems, place heat-resistant polyethylene foam
separately around each refrigerant pipe in the lower part of the indoor unit.

2

Wrap the refrigerant pipes and the drain hose located at the rear of the
indoor unit up in the absorbent pad.

➢ Triply wind the pipes and hose to the end of the indoor unit with

the absorbent pad (make intervals of 20mm / inch).

3

Wind insulating tape around the pipes, assembly cable and drain hose.

4

Place the resulting bundle carefully in the lower part of the indoor unit,
making sure that it does not jut out from the rear of the indoor unit.

5

Hook the indoor unit on to the installation plate and move the unit to the
right and left until you are sure that it is securely in place.

6

Finish wrapping vinyl tape around the rest of the piping leading to the
outdoor unit.

7

Using clamps (optionally supplied), attach the piping to the wall wherever
possible.