4. PTZ SETUP MENU

a. Endless (Left): 360 degree endless scan from the left

b. Endless (Right): 360 degree endless scan from the right

c. Coming and Going : Auto Scan between left limit and right limit (VECTORSCAN)

Select the speed of the Auto scan.

- LEVEL 1: 1.1 deg/sec

- LEVEL 2: 1.2 deg/sec

- LEVEL 3: 1.4 deg/sec

- LEVEL 4: 1.7 deg/sec

- LEVEL 5: 2 deg/sec

- LEVEL 6: 2.5 deg/sec

- LEVEL 7: 3.3 deg/sec

- LEVEL 8: 5 deg/sec

- LEVEL 9: 10 deg/sec

Mode

AUTOSCAN SETUP

NO. 001
MODE
SPEED(PTZ)
START(PTZ)
END (PTZ)
DWELL(SEC)
FOCUS/IRIS

:
: ENDLESS (LEFT)
: 1
: (000.0, 000.00, 001)
:
: 005
: AUTO

00 ========

0123456789

SAVE EXIT

AUTOSCAN SETUP

NO. 001
MODE
SPEED(PTZ)
START(PTZ)
END (PTZ)
DWELL(SEC)
FOCUS/IRIS

:
: COMING & GOING
: 1
: (000.0, 000.00, 001)
: (000.0, 000.00, 00)
: 005
: AUTO

00 ========

0123456789

SAVE EXIT

4

5

3

Start/End

AUTOSCAN SETUP

NO. 001
MODE
SPEED(PTZ)
START(PTZ)

END (PTZ)
DWELL(SEC)
FOCUS/IRIS

: SCAN
: COMING & GOING
: 1
: (000.0, 000.00, 001)

: (000.00, 000.00)
: 005
: AUTO

00 ========

012345678

SAVE EXIT

AUTOSCAN SETUP

NO. 001
MODE
SPEED(PTZ)
START(PTZ)

END (PTZ)
DWELL(SEC)
FOCUS/IRIS

: SCAN
: COMING & GOING
: 1
: (358.26, 041.22, 007)

: (016.52, 276.36)
: 005
: AUTO

00 ========

0123456789

SAVE EXIT

6

7

8

9

Dwell Time

: 05~240 sec.

Focus/Iris

: Auto/Manual

Auto Scan Call

: Input the Auto Scan No. (1~8) and then press the SCAN button to call the Auto Scan

Auto Scan Stop

: If a joystick is connected, move the joystick to stop this function

Advertising