Sterling SDF 250 User Manual

Page 34

Advertising
background image

SDF 250/400/500

Error and error correction 4-4

Error Bypass Flap

The bypass flap does not close or closes too slowly.

Check the bypass flap.

Error Valve Block

The valve block has not reached the proper position. The main switch is placed in the off position.

Check the position of the valve block. Press the “ACK” key and put the main switch in the on
position immediately. If the valve block has not reached the correct position within 1 minute, the
main switch is again placed in the off position.

Sterling Service.

Temperature Measurement Outgoing Air Defective

Check cables and sensor.

Temperature Measurement Return Air Defective

Check cables and sensor.

Excess Temperature Return Air

Check cables and sensor.

Check the return air cooler.

Temperature Measurement Drying Heater Defective

Check cables and sensor.

Check the power supply.

Short circuit check.

Excess Temperature Drying Heater

The drying temperature is too high.

Check the safety temperature limiter.

Sterling Service.

Insufficient Temperature Drying Heater

The drying temperature is too low.

Check the drying heater.

Temperature Measurement Heater Defective Hopper X

(X = number of the drying hopper)

Check cables and sensor.

Check the power supply.

Short circuit check.