10-2. controlling a waveform monitor – Sony BKP-7933 User Manual

Page 52

Advertising
background image

1-46 (E)

BKP-7933

1-10-2. Controlling a Waveform Monitor

A waveform monitor can be controlled from the MSU via the I/O PORT connector of the BKP-7933, by
setting the switches on the IF-689 board of the BKP-7933.

n
The following setting is effective to control a waveform monitor from the MSU that is connected to the

IF-480 board of the CNU-700 in which the BKP-7933 is installed. A waveform monitor cannot be
controlled by the MSU that is connected to the optional IF-480 board (CNU IF board BKP-7930).

1.

Set the switch S2-2 on the IF-689 board to OFF.

When it is set to OFF, remote control mode of the waveform monitor is selected.

2.

Set the switch S2-3 on the IF-689 board in accordance with a waveform monitor in use.
HD ANALOG system waveform monitor (such as Tektronix 1730HD)

ON

RECALL system waveform monitor

OFF

1-10. Using the BKP-7933 in the HD System

IF

RX TX

S-BUS

S-BUS ID No.

S2

CNU GROUP No.

+5

(Component side/A side)

IF-689 board