4. setting switches on the if-689 board – Sony BKP-7933 User Manual

Page 8

Advertising
background image

1-2 (E)

BKP-7933

1-4. Setting Switches on the IF-689 Board

m
. Be sure make the switches settings for the CNU GROUP No. and S-BUS ID No. before turning on the

power. It is no use in setting the switches after turning on the power.

. Do not change the following switches from their factory default settings.

S5-8:

OFF

S201:

1(ON)

Setting of CNU GROUP No.

S3(CNU GROUP No.)

Set the CNU GROUP No. so that it should be unique in a system.
Factory default setting:

2

Setting Examples

1.

When installing the BKP-7933 in the CNU-700 which is provided with the BKP-7930

2.

When using the two CNU-700s which are provided with the BKP-7930

1-4. Setting Switches on the IF-689 Board

CNU GROUP No. 0 (IF-480)

CNU GROUP No. 1 (IF-480)

(IF-689)

Set CNU GROUP No. to 2

CNU GROUP No. 0 (IF-480)

CNU GROUP No. 1 (IF-480)

(IF-689)

Set CNU GROUP No. to 4

CNU GROUP No. 2 (IF-480)

CNU GROUP No. 3 (IF-480)

CNU-700 (2)

AUX1

CNU-700 (1)