Troubleshooting – Sony DSR-1800AP User Manual

Page 98

Advertising
background image

98

Troubleshooting

Chap

ter
6

Maint

ena

nc
e and

T

roub

les
ho
ot

ing

Troubleshooting

If an alarm message appears on the monitor screen, or if
the unit appears to be malfunctioning, please check the
following before contacting your Sony dealer.

a) In these states, an alarm message appears on the monitor screen and in the

time counter display.

a) In these states, an alarm message appears on the monitor screen and in the

time counter display.

Tape problems

Symptom

Cause

Remedy

Recording is not
possible.

The cassette’s REC/SAVE switch is set
to SAVE.

a)

Set the REC/SAVE switch to REC, or use another cassette.

The unit’s tape
transport control
buttons (PLAY, F FWD,
REW, etc.) do not
work.

The REMOTE button is lit and the
LOCAL ENABLE menu item is set to
STOP & EJECT or ALL DISABLE.

a)

Press the REMOTE button to turn it off, or change the setting
of the LOCAL ENABLE menu item

(see page 63) to ALL

ENABLE.

No cassette is loaded.

a)

Insert a cassette

(see page 29).

The NOT EDITABLE
indicator on the front
panel lights up.

The audio recording mode selected on
this unit does not coincide with that of
the loaded tape.

a)

• When your current purpose is editing, press the REMOTE

button to turn it off and set the unit for the same audio
recording mode as with the tape using the REC. MODE
menu item

(see page 69), then turn on the REMOTE

button again.

• When your current purpose is recording, you can use the

tape currently loaded in the unit.

The recording format of the currently
loaded tape is “DV” or “DVCPRO.”

a)

Replace the tape with one recorded in the DVCAM format.

Time data problems

Symptom

Cause

Remedy

Cannot freely set the
initial time data value.

The TC MODE menu item is set to EXT
REGEN.

a)

Change the setting of the TC MODE menu item

(see page

66) to INT PRESET.

CNT is selected as the time data type
to be displayed (the COUNTER time
data type indicator is lit).

a)

Press the COUNTER SEL button to make the TC or U-BIT
time data type indicator light up (the CNT value cannot be
set freely).

The REMOTE button is lit and the
LOCAL ENABLE menu item is set to
STOP & EJECT or ALL DISABLE.

a)

Press the REMOTE button to turn it off or change the setting
of the LOCAL ENABLE menu item

(see page 63) to ALL

ENABLE.

The tape is running,
but the time data is not
shown in the time
counter display.

The MENU button or TC PRESET
button on the menu control panel has
been pressed.

Press the button once again to exit the menu control mode,
time code preset mode, or digital hours meter display mode.
(In either of the menu control mode and time code preset
mode, the time data is not shown in the time counter display.)

The U-BIT time data type indicator is lit. Press the COUNTER SEL button to make the COUNTER or

TC time data type indicator light up.

Monitor problems

Symptom

Cause

Remedy

Data is not
superimposed on the
monitor screen.

The CHARA. DISPLAY menu item is
set to OFF.

Set the CHARA. DISPLAY menu item

(see page 65) to ON.

The monitor is not connected to the
VIDEO OUT 2 (SUPER) connector of
this unit.

Connect the monitor to the VIDEO OUT 2 (SUPER)
connector. (You must make this connection to display any
type of text on the monitor.)

Advertising