100 Mbps Fast Ethernet Collision Domain

SMC 3 - 2 Rule for Class

II

Repeaters

SMC 2 - 1 Rule for Class

I

and Class

II

Repeaters

Maximum 100BASE-T Network Diameter*

Maximum 100BASE-T Cable Distance

I

NSTALLING

4-10

Between any two PCs or other stations in the same
100BASE-T collision domain, there may be:

• up to 3 link segments and

• up to 2 Class

II

repeaters (hubs)

Between any two PCs or other stations in the same
100BASE-T collision domain, there may be:

• up to 2 link segments and

• up to 1 Class

I

or Class

II

repeater (hub)

Repeater Type

Twisted Pair

Twisted Pair/Fiber

and Number

100BASE-TX/T4 100BASE-T4/FX

100BASE-TX/FX

1 Class I

200 m (656 ft.)

231 m (757.7 ft.)

260.8 m (855.4ft.)

1 Class II

200 m (656 ft.)

304 m (997.1 ft.)

308.8 m (1012.9 ft.)

2 Class II

205 m (672.4 ft.)

236.3 m (775.1 ft.) 216.2 m (709.1 ft

.)

Cable Type

Connecting

Max. Distance

Twisted Pair

Any two devices

100 m (328 ft.)

Fiber

Switch to Switch, Server or PC

Half duplex

412 m (1,351.4 ft.)

Full duplex

2 km (1.24 mi.)

MII

Any two devices

0.5 m (1.6 ft.)

*Note: Network Diameter is defined as the wire distance between two end stations in
the same collision domain.