System programming, Entering system programming, Default reset – ScyTek Electronics 1000RS User Manual

Page 19: Programmable system options

Advertising
background image

Astra 1000RS - Page 15

Entering System Programming

To enter System Programming:

1. Turn on ignition.
2. Within 5 seconds, press the valet switch 5 times.

· The parking lights will flash three (3) times indicating you have entered Programming.

3. Press the valet switch the number times equal to the System Parameter you want to change.

· The parking lights will flash each time the valet switch is pressed.

4. Within 5 seconds, press the transmitter button corresponding to the desired operating mode for

that System Parameter.

· The parking lights will flash to indicate the setting.

1 flash

=

Button 1

2 flashes

=

Button 2

3 flashes

=

Button 3

5. When you are finished, turn off the ignition to save the changes.

Default Reset

Following this procedure will set all System Programming Parameters to factory default settings.

1. Enter System Programming.
2. Press Transmitter Button 3.

· The parking lights will flash 6 times indicating that the reset signal was received.
· All System Programming parameters are now set to factory default settings.
· The Valet Mode is off.

3. Turn off ignition.

Programmable System Options

The following is a description of the programming options of the system. Some of the program branches

control more than one option, and may require accessing a particular branch number twice in order to

program all desired features.
1. Ignition Door Locking. Selects whether or not the system will automatically lock the doors 5 seconds

after the ignition key is turned on.

2. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when

the ignition is turned off.

3. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.

Many new import vehicles’ factory door locking systems require two pulses on the proper wire to unlock

the doors. These systems can be interfaced directly without the use of relays or any additional circuitry

by programming the system for double unlock pulse.

4. Door Lock Pulse Length. Selects between a 1, 3 and 0.1 second output for door locking and

unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.

5. Aux 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.

System Programming