Errors – Sony STORSTATION LIB-D81 User Manual

Page 30

Advertising
background image

30

Chapter 3 Basic Usage

High internal temperature

The ERROR/WARNING LED lights orange and the [0 6] code appears on the
message display. Suspend operation or lower ambient temperature. When the
AIT autoloader internal temperature returns to normal levels, the ERROR/
WARNING LED goes out. It is possible for the air filter to become clogged with
dust or other particles. To prevent this from happening, be sure to clean the air
filter regularly. For details, see “Maintenance” (page 33).

Specific parts have reached the end of their service life

The ERROR/WARNING LED lights orange and the [0 7] code appears on the
message display. Contact customer service.

Errors

When an error occurs in the AIT autoloader, the ERROR/WARNING LED
flashes orange and an error code appears on the message display. For
information about error codes, see “Error Code List” (page 47) in the
“Appendix”.

Example: Problem with a cartridge

[C ] and [XX], where “XX” is the error code, appear alternatively on the
message display.

Example: Problem with the autoloader

[L ] and [XX], where “XX” is the error code, appear alternately on the message
display.

WARNING

CLEANING

ERROR

WARNING

CLEANING

ERROR

Advertising