Sony STORSTATION LIB-D81 User Manual

Page 51

Advertising
background image

51

Appendix

C0

Detected a check sum
anomaly during microcode
update.

Yes

C1

Detected a F/W ID anomaly
during microcode update.

Yes

C8

Detected a timeout when
ejecting the media from the
drive.

[L ] and [E 8] appear
alternately on the message
display.

Yes

E0

Cannot write data to flash
memory within 1 ms.

[L ] and [E 0] appear
alternately on the message
display.

Yes

E1

Cannot clear flash memory
sectors within 10 s.

[L ] and [E 1] appear
alternately on the message
display.

Yes

E8

Detected a check sum
anomaly in the flash memory
device setting area.

[L ] and [E 0] appear
alternately on the message
display.

No

F0

Detected a GAP sensor
anomaly.

[L ] and [F 0] appear
alternately on the message
display.

Yes

F1

Detected a pass sensor
anomaly.

[L ] and [F 1] appear
alternately on the message
display.

Yes

F2

Detected a cartridge sensor
anomaly.

[L ] and [F 2] appear
alternately on the message
display.

Yes

F3

Detected a picker forward
sensor anomaly.

[L ] and [F 3] appear
alternately on the message
display.

Yes

F4

Detected a picker reverse
sensor anomaly.

[L ] and [F 4] appear
alternately on the message
display.

Yes

F5

Detected an elevator lower
sensor anomaly.

[L ] and [F 5] appear
alternately on the message
display.

Yes

F6

Detected a door lock sensor
anomaly.

[L ] and [F 6] appear
alternately on the message
display.

Yes

F7

Detected a door close sensor
anomaly.

[L ] and [F 7] appear
alternately on the message
display.

Yes

Error code Description

Display

Logged