Rec out parameter request command, Remote command – Sony RS-232C User Manual

Page 51

Advertising
background image

– 51 –

REC OUT PARAMETER REQUEST : 52[H] 4F[H] 4D[H] 33[H],32[H] (‘ROR1,2’)

This command is used to read parameter of the desired single channel of the REC OUT 1 and 2 from the SRP-X700P.
The commands that correspond to the respective channels are shown below.

Packet format

52[H] 4F[H] 52[H] 31[H] “parameter” 0D[H]
(In the case of REC OUT 1)

Parameter

Specify the scene No. of the scene memory that you want to read, as the parameter.
Method of specifying the scene No. is the same as that of the GROUP FADER command. See page 29.

Return packet format

When communication with the SRP-X700P is established with success, the parameter is returned together with ACK (41[H] (‘A’)) in the
order shown below.

41[H] “parameter” 0D[H]

The parameter is the same as the 9 bytes of the REC OUT1, 2 commands’ parameter from which the scene No. is exempted.

REMOTE : 43[H] 53[H] 49[H] 4F[H] (‘CSIO’)

This command is used to set the CONTROL S OUTPUT and the PROJECTOR CONTROL.

Packet format

43[H] 53[H] 49[H] 4F[H] “parameter” 0D[H]

Parameter

The parameter consists of the 24 bytes all the time in the order as shown in the table below.
The 24th byte should always be set to the fixed value (30[H] (‘0’)).

CHANNEL

Command

REC OUT 1

52[H] 4F[H] 52[H] 31[H] ‘ROR1’

REC OUT 2

52[H] 4F[H] 52[H] 32[H] ‘ROR2’

byte

byte

1st

LINE3 MACHINE TYPE

13th

LINE4F MACHINE TYPE

2nd

LINE3 CONNECTED CHANNEL

14th

LINE4F CONNECTED CHANNEL

3rd

LINE4A MACHINE TYPE

15th

CONTROL S I/F TYPE

4th

LINE4A CONNECTED CHANNEL

16th

PJ CONTROL

5th

LINE4B MACHINE TYPE

17th

LINE4 A SIGNAL DEFINE

6th

LINE4B CONNECTED CHANNEL

18th

LINE4 B SIGNAL DEFINE

7th

LINE4C MACHINE TYPE

19th

LINE4 C SIGNAL DEFINE

8th

LINE4C CONNECTED CHANNEL

20th

LINE4 D SIGNAL DEFINE

9th

LINE4D MACHINE TYPE

21st

LINE4 E SIGNAL DEFINE

10th

LINE4D CONNECTED CHANNEL

22nd

LINE4 F SIGNAL DEFINE

11th

LINE4E MACHINE TYPE

23rd

PROJECTOR PROTOCOL

12th

LINE4E CONNECTED CHANNEL

24th

30[H] (‘0‘) fixed

Advertising