Routing command – Sony RS-232C User Manual

Page 54

Advertising
background image

– 54 –

ROUTING : 43[H] 52[H] 4C[H] 31[H]-38[H] (‘CRL1-8’)

43[H] 52[H] 52[H] 31[H]-32[H] (‘CRR1-2’)

This command is used to set the routing for the OUTPUT channels.
Various setups can be memorized in the scene memories by specifying these scene Nos.
The commands that correspond to the respective channels are shown below.

Packet format

43[H] 52[H] 4C[H] 31[H] “parameter” 0D[H]

(In the case of LINE OUTPUT1)

Parameter

The parameter consists of the 20 bytes all the time in the order as shown in the table below.

When you specify NONE (30[H] ‘0’) as the scene No. in the 1st byte, you can establish the present setup.
At the same time, when you specify the scene No.(31[H] (‘1’) through 44[H] (‘D’)), parameters of the subsequent 2nd through 20th byte
are written in the scene memory.

For the method of setting the scene No., see the GROUP FADER command (pages 29 and 30).

CHANNEL

Command

LINE OUTPUT 1

43[H] 52[H] 4C[H] 31[H] ‘CRL1’

LINE OUTPUT 2

43[H] 52[H] 4C[H] 32[H] ‘CRL2’

LINE OUTPUT 3

43[H] 52[H] 4C[H] 33[H] ‘CRL3’

LINE OUTPUT 4

43[H] 52[H] 4C[H] 34[H] ‘CRL4’

LINE OUTPUT 5

43[H] 52[H] 4C[H] 35[H] ‘CRL5’

LINE OUTPUT 6

43[H] 52[H] 4C[H] 36[H] ‘CRL6’

LINE OUTPUT 7

43[H] 52[H] 4C[H] 37[H] ‘CRL7’

LINE OUTPUT 8

43[H] 52[H] 4C[H] 38[H] ‘CRL8’

REC OUT 1

43[H] 52[H] 52[H] 31[H] ‘CRR1’

REC OUT 2

43[H] 52[H] 52[H] 32[H] ‘CRR2’

byte

Parameter name

byte

Parameter name

1st

SCENE No.

11 th

LINE4 A-C,F R LEVEL

2nd

MIC1/WL1 LEVEL

12 th

LINE4 D-E L LEVEL

3rd

MIC2/WL2 LEVEL

13 th

LINE4 D-E R LEVEL

4th

MIC3 LEVEL

14 th

LINE4 D-E LS LEVEL

5th

MIC4 LEVEL

15 th

LINE4 D-E RS LEVEL

6th

MIC5/LINE1 LEVEL

16 th

LINE4 D-E C LEVEL

7th

MIC6/LINE2 LEVEL

17 th

LINE4 D-E SW LEVEL

8th

LINE3 L LEVEL

18 th

MIC1/WL1-MIC6/LINE2 ON/OFF

9th

LINE3 R LEVEL

19 th

LINE3-LINE4A-C ON/OFF

10th

LINE4 A-C,F L LEVEL

20 th

LINE4 D,E ON/OFF

Advertising