INSTALLATION

20221081 / F

9

3. INSTALLATION

3.1 General

The following parts are supplied with a standard HS50 system:

− Sensor unit with 1 meter cable w/connector and 4

fastening bolts

− Display unit with 15 meters cable to the Processing

unit and flush mounting kit

− Processing unit including 4 fastening screws
− 30 meters cable to be used between Sensor unit and

Processing unit

− Documentation

Caution!
The Sensor unit has to be mounted in a way that
avoids blocking of the GPS signal.
The Processing and Display Unit can be
mounted on the bridge or in the instrument
room.

No units should be exposed to heavy vibration,
transformers or similar.

3.2 Cable connection

Use only shielded cables for the installation. This includes
power input and signal cables. The cables should be of 0.5 mm

2

(AWG20) twisted pairs.

The cable to the Display unit and other cables (NMEA
input/output, Ethernet) should not be run in parallel with other
cables carrying RF or high current, such as VHF and SSB
transmitters, battery charges/generators and winches.

3.3 Grounding

All units in the HS50 system use the Processing unit as a
common ground/shield connection. The Processing unit should
therefore have a proper ground connection to the hull/bonding
system.