Checking electrical components, 1. measurement of insulation resistance – Sanyo STB1220C1 User Manual

Page 39

Advertising
background image

35

8-1. Measurement of Insulation

Resistance

The insulation is in good condition if the resistance
exceeds 2M

.

8-1-1. Power Cord and Unit

Clamp the grounding prong of the power plug with a lead

clip of the insulation resistance tester and measure the

resistance by placing a probe on either of the two power

blade. (Fig. 1)

Then, also measure the resistance between the

grounding prong and other power blade. (Fig. 1)

8-1-2. Measurement of Insulation

Resistance for Electrical Parts

Disconnect the lead wires of the desired electric part

from terminal plate, switch, capacitor, etc. Similarly

disconnect the connector. Then measure the insulation

resistance.

(Figs. 2 to 3)

Refer to Electric Wiring Diagram.

If the probe cannot enter the poles because the hole is

too narrow then use a probe with a thinner pin.

NOTE

Power plug

Ground

Probe

Insulation tester

Fig. 1

Copper
tube or
metallic part

Clip

Insulation
tester

Probe

Fig. 2

Clip

Insulation
tester

Probe

Metallic
part

From fan motor,
compressor and
other parts

Fig. 3

Fig. 4