INSTALLATION

INSTALLATION SAFETY INFORMATION:

Read these instructions before continuing this appli-
ance installation. This is an outdoor combination heat-
ing and cooling unit. The installer must assure that
these instructions are made available to the consumer
and with instructions to retain them for future reference.

1.

Refer to the unit rating plate for the approved type
of gas for this unit.

2.

Install this unit only in a location and position as
specified on Page 10 of these instructions.

3.

Never test for gas leaks with an open flame. Use
commercially available soap solution made specifi-
cally for the detection of leaks when checking all
connections, as specified on Pages 8, 16, 17 and
40 of these instructions.

4.

Always install unit to operate within the furnace's
intended temperature-rise range with the duct sys-
tem and within the allowable external static pres-
sure range, as specified on the unit name/rating
plate, specified on Page 42 of these instructions.

5.

This equipment is not to be used for temporary
heating of buildings or structures under construc-
tion.

LIMITATIONS

These units must be installed in accordance with the
following national and local safety codes:

In U.S.A.:

National Electrical Code ANSI/NFPA No. 70.

National Fuel Gas Code Z223.1.

Gas-Fired Central Furnace Standard ANSI
Z21.47a.

Local gas utility requirements.

In Canada:

Current Canadian Electrical Code C22.1.

Current Gas Installation Codes CSA-B149.1.

Local plumbing and waste water codes.

Other applicable local codes.

Refer to the Unit Application Data table and to the Gas
Heat Application Data table.

After installation, the unit must be adjusted to obtain a
temperature rise within the range specified on the unit
rating plate.

If components are to be added to a unit to meet local
codes, they are to be installed at the dealer's and/or
the customer's expense.

Size of unit for proposed installation should be based
on heat loss/heat gain calculation made according to
the methods of the Air Conditioning Contractors of
America (ACCA).

This equipment is not to be used for temporary heating
of buildings or structures under construction.

International:

Local Government/Agency Regulations

FIRE OR EXPLOSION HAZARD

FAILURE TO FOLLOW THE SAFETY WARN-
ING EXACTLY COULD RESULT IN SERIOUS
INJURY, DEATH OR PROPERTY DAMAGE.

NEVER TEST FOR GAS LEAKS WITH AN
OPEN FLAME. USE A COMMERICALLY
AVAILABLE SOAP SOLUTION MADE SPE-
CIFICALLY FOR THE DETECTION OF
LEAKS TO CHECK ALL CONNECTIONS. A
FIRE OR EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.