Product nomenclature – Sunlife Enterprises SUNLINE DM180 User Manual

Page 6

Advertising
background image

356214-XIM-A-0108

6

Johnson Controls Unitary Products

PRODUCT NOMENCLATURE

D M 180 N24 A 7 A AA 1 0 1 2 4 A

D = A/C, Single Pkg., R-22

Product Category

A = Std. Drive

Airflow

B = Std. Drive/Single Input Econo.
C = Std. Drive/Single Input Econo./Power Exhaust

(Downflow Only)

D = Std. Drive/Motorized Damper

N = Hi Static Drive*
P = Hi Static Drive/Single Input Econo.
Q = Hi Static Drive/Single Input Econo./Power Exhaust

(Downflow Only)

R = Hi Static Drive/Motorized Damper

* Note: 50 Hz, DM180 -300 Models

come standard with high
static drive package.

1 = First Generation

Product Generation

2 = Second Generation

C00 = Cooling Only. No field installed

electric heat

Heat Type and Nominal Heat Capacity

N24 = 240 MBH Output Aluminized Steel
N32 = 320 MBH Output Aluminized Steel

S24 = 240 MBH Output Stainless Steel
S32 = 320 MBH Output Stainless Steel

E18 = 18 KW
E36 = 36 KW

E54 = 54 KW
E72 = 72 KW

Gas Heat Options

Electric Heat Options

180 = 15 Ton

Nominal Cooling Capacity

240 = 20 Ton

300 = 25 Ton

Product Identifier

M = 8.5-9.0 EER A/C

Voltage

7 = 380/415-3-50

Product Style

A = Style A

A = No Options Installed

Installation Options

B = Option 1
C = Option 2

D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5

1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet

Options

SS Drain Pan

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

CPC Controller, DFS, APS

Johnson Controller, DFS, APS

Honeywell Controller, DFS, APS

Novar Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

2" Pleated filters

4" Pleated filters

BAS Ready Economizer (2-10 V.D.C. Actuator Without a Controller)

Double Wall Construction

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

AA = None

Standard Cabinet

AB = Phase Monitor
AC = Coil Guard

AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
RC = Coil Guard & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils

BA = Hinged Filter Door & Tool Free Access Panels

Additional Options

Hinged Filter Door & Tool Free Access Cabinet

BB = Phase Monitor, Hinged Filter Door & Tool Free

Access Panels

BC = Coil Guard, Hinged Filter Door & Tool Free

Access Panels

BD = Dirty Filter Switch, Hinged Filter Door &

Tool Free Access Panels

BE = Phase Monitor & Coil Guard, Hinged Filter

Door & Tool Free Access Panels

BF = Phase Monitor & Dirty Filter Switch, Hinged

Filter Door & Tool Free Access Panels

BG = Coil Guard & Dirty Filter Switch, Hinged Filter

Door & Tool Free Access Panels

BH = Phase Monitor, Coil Guard & Dirty Filter Switch,

Hinged Filter Door & Tool

Free

Access Panels

15-25 Ton Sunline & Magnum™ & MagnaDRY™ Model Number Nomenclature

ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be

located in digits 15-18.

E = Std. Drive/Motorized Damper/Barometric Relief

J = Std. Drive/Single Input Econo./Barometric Relief

K = Hi Static Drive/Motorized Damper/Barometric Relief
S = Hi Static Drive/Single Input Econo./Barometric Relief