Gas supply, Gas requirements, Upply – Southbend X560DD S536A User Manual

Page 5

Advertising
background image

500

S

ERIES

R

ESTAURANT

R

ANGES

S

PECIFICATIONS

O

WNER

S

M

ANUAL

1188716

(09/07) P

AGE

5

OF

48

G

AS

S

UPPLY

A 3/4" female NPT gas connection is located on the rear of the range (see Figure 2).

The serial plate is located on the right side of the range (See Figure 1). The serial plate indicates the type of gas the
range is equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.

These models are design-certified for operation on natural or propane gases. For natural gas, the regulator is set to 4"
W.C. (0.99 kPa). For propane gas, it is set to 10" W.C. (2.48 kPa).

If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance
with local codes, or in the absence of local codes, with the applicable national codes.

This appliance should be connected ONLY to the type of gas for which it is equipped.

An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems
and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold
pressure.

An adequate gas supply line to the range should be no smaller than the inside diameter of the pipe from the range to
which it is connected.

Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the range.

All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases.
NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the range has
been put into operation. Test pressure should not exceed 14" W.C. (3.47 kPa).

G

AS

R

EQUIREMENTS

Burners (number of and BTU/hour)

Model Number

Open Oven Griddle

Total BTU/hour

536A

6@27,000 Nat

6@21,000 LP

1@32,000 Nat

1@30,000 LP

-

194,000 Nat

156,000 LP

536D

6@27,000 Nat

6@21,000 LP

1@45,000 Nat

1@40,000 LP

-

207,000 Nat

166,000 LP

560AA

10@27,000 Nat

10@21,000 LP

2@32,000 Nat

2@30,000 LP

-

334,000 Nat

270,000 LP

560DD

10@27,000 Nat

10@21,000 LP

2@45,000 Nat

2@40,000 LP

-

360,000 Nat

290,000 LP

560AA-2GR

560AA-2TR

6@27,000 Nat

6@21,000 LP

2@32,000 Nat

2@30,000 LP

3@16,000 Nat

3@16,000 LP

274,000 Nat

234,000 LP

560DD-2GR

560DD-2TR

6@27,000 Nat

6@21,000 LP

2@45,000 Nat

2@40,000 LP

3@16,000 Nat

3@16,000 LP

300,000 Nat

254,000 LP