Exterior dimensions, Interior dimensions and utility connections, Ventilation – Southbend X560DD S536A User Manual

Page 7: Warning, Notice, Entilation

Advertising
background image

500

S

ERIES

R

ESTAURANT

R

ANGES

S

PECIFICATIONS

O

WNER

S

M

ANUAL

1188716

(09/07) P

AGE

7

OF

48

E

XTERIOR

D

IMENSIONS

Exterior Dimensions in Inches and (Millimeters)

Model Number

A B C D E F G H I J K

Cook Top

Height

L

Door

Depth

M

Oven

Bottom

N

536A

36.5"
(927)

45.25"
(1149)

10"

(254)

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

536D

36.5"
(927)

36"

(914)

-

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

560AA
560AD

60.75"
(1543)

45.25"
(1149)

10"

(254)

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

560DD

60.75"
(1543)

36"

(914)

-

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

560AA-2GR

560AA-2TR

60.75"
(1543)

45.25"
(1149)

10"

(254)

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

560DD-2GR

560DD-2TR

60.75"
(1543)

36"

(914)

-

31.25"

(794)

33"

(838)

11"

(279)

2.75"

(70)

59.5"

(1511)

22.5"
(587)

31.0"
(787)

6"

(152)

37.0"
(914)

15.5"
(394)

13"

(318)

See table below for dimensions O, P, Q, and R.

I

NTERIOR

D

IMENSIONS AND

U

TILITY

C

ONNECTIONS

Left (or Only) Oven

Interior Dimensions

Right Oven

Interior Dimensions

Gas Connection

Location

Electric Connect.

Location

Model Number

Width Depth Height Width Depth Height O*

P*

Q*

R*

536A

26.125”

(664)

24”

(610)

14.25”

(362)

- - -

3.25”

(82)

30.25”

(768)

24”

(610)

6”

(152)

536D

26”

(660)

26.5”
(673)

14”

(356)

- - -

3.25”

(82)

30.25”

(768)

- -

560AA

26.125”

(664)

24”

(610)

14.25”

(362)

26.125”

(664)

24”

(610)

14.25”

(362)

3.25”

(82)

30.25”

(768)

24”

(610)

6”

(152)

560DD

26”

(660)

26.5”
(673)

14”

(356)

26”

(660)

26.5”
(673)

14”

(356)

3.25”

(82)

30.25”

(768)

- -

560AA-2GR

560AA-2TR

26.125”

(664)

24”

(610)

14.25”

(362)

26.125”

(664)

24”

(610)

14.25”

(362)

3.25”

(82)

30.25”

(768)

24”

(610)

6”

(152)

560DD-2GR

560DD-2TR

26”

(660)

26.5”
(673)

14”

(356)

26”

(660)

26.5”
(673)

14”

(356)

3.25”

(82)

30.25”

(768)

- -

* See figure on previous page for location of utility connections.

V

ENTILATION

WARNING

Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products
can cause headaches, drowsiness, nausea, or could result in death.

All ranges must be installed in such a manner that the flow of combustion and ventilation air are not obstructed.
Provisions for adequate air supply must be provided. Do not obstruct the front of the range at the top by the control
panel, or the bottom just below the oven compartment, as combustion air enters through these areas.

NOTICE

Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the
warranty.

Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s
instructions.

Canopies are set over ranges, ovens, etc., for ventilation purposes. It is recommended that a canopy extend 6" past
the appliance and the bottom edge be located 78" above the floor. Filters should be installed at an angle of 45° or
more from the horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip
pan, unusually installed with a filter.

Advertising