Troubleshooting convection-oven blower, Warning, Caution – Southbend X560DD S536A User Manual

Page 24: Convection-oven blower runs intermittently, Roubleshooting, Onvection, Lower

Advertising
background image

S

ERVICE

500

S

ERIES

R

ESTAURANT

R

ANGES

P

AGE

24

OF

48 O

WNER

S

M

ANUAL

1188716

(09/07)

T

ROUBLESHOOTING

C

ONVECTION

-O

VEN

B

LOWER

WARNING

Before attempting to service or replace any electrical component, make sure power source has been
disconnected.

CAUTION

When changing motor or servicing range, always verify that blower wheel rotation is clockwise when looking into
the oven cavity.

The motor is serviceable from the front of the range through the oven cavity. Remove the back lining. Disconnect the
motor mount plate by removing the eight hex nuts that secure it to the oven interior back. Pull the mount plate, with
motor attached, into the oven.

Motor lubrication information can be found on permanent label located on motor.

If the blower does not run at all, consult the flowchart that begins on the next page. If the blower runs intermittently,
consult the flowchart on this page.

The appropriate wiring diagram for the oven can be found on the rear of the oven (as well as at the end of this section of
this manual).

Figure 10

Convection-Oven Blower Runs Intermittently

DISCONNECT POWER AT CIRCUIT BREAKER.

Convection-oven blower runs intermittently.

Check that there are no air-flow obstructions around the range.

Does the problem

occur only when the oven

is hot?

No

Yes

Check that the blower motor air vents are not obstructed.

Check that the blower motor is not pressing against the wall

behind the range.

Check for excessive grease and dust buildup on the motor.

Check for sources of excessive heat behind the range.

Check for hot-air leaks around the motor pocket.

Check all wiring for loose connections or breaks.

With the blower turned ON, turn the oven thermostat to OFF and

allow the oven to cool. If the blower motor runs continuously

when the oven is cool, turn the oven thermostat to the highest

setting. If the blower motor shuts off when the oven becomes hot,

and if there are no sources of excessive heat around the blower

motor, replace the blower motor.

Remove the cover from the junction box on the back of the range.

Disconnect the black wire and place an ammeter in the circuit.

CAUTION: Check that the ammeter is rated for at least 40

amperes! Reconnect the power to the range and turn on the

blower switch while watching the ammeter. The reading should

surge and then return to the rated current of the motor when

running at high speed. If the measured current exceeds the motor

rating, replace the blower motor.

Advertising
This manual is related to the following products: