SRP-X500P RS-232C Interface Manual

TEMPERATURE (78th and 79th byte)

The TEMPERATURE parameter consists of 2 bytes of data in the order shown in the following table.

Byte Parameter

1st

SPEAKER OUTPUT CH1/2 TEMPERATURE

2nd

SPEAKER OUTPUT CH3/4 TEMPERATURE

TEMPERATURE

Shows the temperature of the heat sink in the power amplifier section.
The correspondence of the parameter with the temperature is shown in the following table.

Temperature

Less than30℃ 0x30

(‘0’)

30-34℃ 0x31

(‘1’)

35-39℃ 0x32

(‘2’)

40-44℃ 0x33

(‘3’)

45-49℃ 0x34

(‘4’)

50-54℃ 0x35

(‘5’)

55-59℃ 0x36

(‘6’)

60-64℃ 0x37

(‘7’)

65-69℃ 0x38

(‘8’)

70-74℃ 0x39

(‘9’)

75-79℃ 0x3A

(‘:’)

80-84℃ 0x3B

(‘;’)

85-89℃ 0x3C

(‘<‘)

90-94℃ 0x3D

(‘=‘)

95-99℃ 0x3E

(‘>‘)

100℃ or more

0x3F (‘?’)

PROJECTOR ON/STANDBY INDICATOR (80th byte)

Shows the status of the PROJECTOR ON/STANDBY POWER switch on the front panel of the SRP-
X500P.
The parameter and the status of the PROJECTOR ON/STANDBY POWER switch are shown in the
following table.

PROJECTOR ON/STANDBY INDICATOR

STANDBY (The switch lights up red.)

0x30 (‘0’)

ON (The switch lights up red.)

0x31 (‘1’)

Cooling down before entering STANDBY (The switch flashes green.)

0x32 (‘2’)

EMG MUTING (83rd byte)

Shows the muting status of the REMOTE PARALLEL connector using the EMG function.
The parameter and the muting status using the EMG function are shown in the following table.

EMG MUTING

Muting off

0x30(‘0’)

Muting on

0x31(‘1’)