Factory preset : 0x43 0x52 0x53 0x54 (‘crst’), Factory preset – Sony SRP-X500P User Manual

Page 43

Advertising
background image

SRP-X500P RS-232C Interface Manual

Example

When the version is 1.00

0x41 0x31 0x2E 0x30 0x30 0x20 0x20 0x20 0x20 0x20
(‘A 1 . 0 0 □ □ □ □’)

“□” indicates a space.

2.3.6 FACTORY PRESET : 0x43 0x52 0x53 0x54 (‘CRST’)

This command is used to restore the parameters of the SRP-X500P to their factory default setting.

When this command is transmitted, all parameters of the SRP-X500P return to their factory default setting,
including the scene memory settings.

Packet format

0x43 0x52 0x53 0x54 0x0D

Parameter

The FACTORY PRESET command does not require the addition of a parameter.

Example

To return to the SRP-X500P to its factory preset settings:
0x43 0x52 0x53 0x54 0x0D
(‘C R S T CR’)

Note

When the SRP-X500P has received the command successfully, it returns an ACK (0x41 (‘A’)) after about 5
seconds.
Do not transmit any other commands until the SRP-X500P receives an ACK (0x41 (‘A’)).
After confirming that an ACK (0x41 (‘A’)) has been returned, restart the SRP-X500P.



















9-870-520-11

Page 43/43