Remove the pro, Maintenance indicators – Sharp XG-PH50X User Manual

Page 96

Advertising
background image

-92

Maintenance indicator

Problem

Cause

Possible solution

Temperature

warning

indicator

Normal

Abnormal

Off

Red on

(Standby)

The internal
temperature is
abnormally high.

Abnormal

• Blocked air intake

• Relocate the projector to an area

with proper ventilation. (See page

9

.)

• Cooling fan break-

down

• Internal circuit failure
• Clogged air intake
• Clogged intake vent

cover

• Take the projector to your nearest

Sharp Authorized Projector Dealer
or Service Center for repair. (See
page

101

.)

• Clean the air vents and the intake

vent cover. (See page

90

.)

Lamp

indicators

1, 2

Red on

(Standby)

The lamp does
not illuminate.

• Burnt-out lamp
• Lamp circuit failure

• Carefully replace the lamp. (See

page

94

.)

• Take the projector to your nearest

Sharp Authorized Projector Dealer
or Service Center for repair. (See
page

101

.)

• Please exercise care when

replacing the lamp.

Red on

Time to change
the lamp.

• Remaining lamp life

becomes 5% or less.

Green on

Green blinks

when the lamp

is warming up.

Info

• If the temperature warning indicator blinks and the projector enters the standby mode, the temperature

warning indicator starts to illuminate. Check whether any of the ventilation holes are blocked (see page

9

)

and then try turning the power back on. Wait until the projector has cooled down completely before
plugging in the power cord and turning the power back on. (At least 10 minutes.)

• If the power is turned off for a brief moment due to power outage or some other cause while using the

projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red
and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power
cord in the AC outlet and then turn the power on again.

• Do not unplug the power cord after the projector has entered the standby mode and while the cooling fan

is running. The cooling fan runs for about 90 seconds.

The lamp does
not illuminate.

• The lamp is shut

down abnormally.

• Disconnect the power cord from

the AC outlet, and then connect it
again.

Maintenance Indicators

Power

indicator

Green on/

Red on

Red
blinks

The power
indicator blinks in
red when the
projector is on.

••••• The intake vent

cover is open.

••••• Securely install the cover.
••••• If the power indicator blinks even

when the intake vent cover is
securely installed, contact your
nearest Sharp Authorized Projector
Dealer or Service Center for
advice. (See page

101

.)

Advertising