Senatek HELLODEVICE LITE SERIES LS100 User Manual

Page 15

Advertising
background image

15

Figure 2-6. Data/Console switch of the LS100

4) Run a terminal emulator program such as HyperTerminal. Set up the serial configuration

parameters of the terminal emulation program as follows:

9600 Baud rate, Data bits 8, Parity None, Stop bits 1, Hardware flow control

5) Press [ENTER] key.

6) Type the user name and password to log into the LS100. A factory default setting of the

user name and password are both admin.

7) If the user logged into the LS100 successfully, command prompt screen will appear on the

computer as shown in Figure 2-7.


login: admin
password: *****
Type 'help' to get command usages
> help
set group par1 [par2 ...] + <CR>
- group = 'ip','host','serial' or 'admin'
- par1 ... = configuration parameters. Use * to keep a parameter's value
get [group] + <CR>
- group = 'ip','host','serial','admin' or 'status'
- If group is specified, shows settings of the group.
- If group is omitted, shows settings of all groups.
factorydefault [option] + <CR>
- if option is omitted, all parameters are set with factory default values.
- if option='-ip',

all parameters except IP settings are set with factory default values.

help [group] + <CR>
- If group is omitted, shows this screen.
- If group is specified, shows 'set' command usage of the group.
save + <CR>
- Save changes
exit + <CR>
- Exit without rebooting the device
reboot + <CR>
- Exit and reboot the device

>

Figure 2-7. The LS100 console screen