Installing the Rack Rails:

Determine where you want to place the SuperServer 6025B-UR in the rack. (See

Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail

guide assemblies (made up of two inter-locking sections) at the desired location in

the rack, keeping the sliding rail guide facing the inside of the rack and the rollers

toward the front of the rack. Screw the assembly securely to the rack. Attach the

other assembly to the other side of the rack, making sure both are at the exact

same height and with the rail guides facing inward.

Installing the Server into the Rack

You should now have rails attached to both the chassis and the rack unit. The next

step is to install the server into the rack. Do this by lining up the rear of the chas-

sis rails with the front of the rack rails. Slide the chassis rails into the rack rails,

keeping the pressure even on both sides (you may have to depress the locking

tabs when inserting). See Figure 2-2.

When the server has been pushed completely into the rack, you should hear the

locking tabs "click". Finish by inserting and tightening the thumbscrews that hold

the front of the server to the rack.

Installing the Server into a Telco Rack

If you are installing the SuperServer 6025B-UR into a Telco type rack, follow the di-

rections given on the previous pages for rack installation. The only difference in the

installation procedure will be the positioning of the rack brackets to the rack. They

should be spaced apart just enough to accommodate the width of the telco rack.