Siemens PC 670 User Manual

Page 153

Advertising
background image

Hardware Information

Release 04/02

7-21

Panel PC 670 Computing Unit, Equipment Manual

Display port (LVDS), X400

TFT displays with an LVDS port can be connected to this port. 18-bit displays
having a resolution up to 1024x768 pixels can be connected. The permissible
display clock rate is 20 MHz to 66 MHz. The display is selected automatically
according to the code of the Display Select inputs. The display supply voltages
(3,3 V and 5 V) are connected as a function of the requirements for the connected
displays via the graphics controller. The maximum cable length is 50 cm at a
transfer rate of 455 MHz. Specific cable properties have to be taken into account
for differential cable pairs in accordance with the LVDS specification.

Pin
No.

Short Name

Meaning

Input/Output

1

P5V_D_fused

+5V (fused) Display VCC

Output

2

P5V_D_fused

+5V (fused) Display VCC

Output

3

RXIN0–

LVDS output signal bit 0 (-)

Output

4

RXIN0+

LVDS output signal bit 0 (+)

Output

5

P3V3_D_fused

+3.3V (fused) display VCC

Output

6

P3V3_D_fused

+3.3V (fused) display VCC

Output

7

RXIN1–

LVDS output signal bit 1 (-)

Output

8

RXIN1+

LVDS output signal bit 1 (+)

Output

9

GND

Chassis ground

-

10

GND

Chassis ground

-

11

RXIN2–

LVDS output signal bit 2 (-)

Output

12

RXIN2+

LVDS output signal bit 2 (+)

Output

13

GND

Chassis ground

-

14

GND

Chassis ground

-

15

RXCLKIN–

LVDS clock signal (–)

Output

16

RXCLKIN+

LVDS clock signal (+)

Output

17

GND

Chassis ground

-

18

GND

Chassis ground

-

19

Reserved

20

Reserved

Advertising