Connecting and Switching on the Computing Unit

Release 04/02

3-21

Panel PC 670 Computing Unit, Equipment Manual

Connecting the computing unit to programming units (TTY)

In order to connect the computing unit, connect the corresponding connection
cable to the TTY interface.

Table 3-2

Connecting the computing unit to other programming units

Interface

Connection

Connecting cable

Order No.

Adapter

COM 1 as TTY
port

with PG 6xx

Series connection of
6ES5 733 -2xxx0

2)

and
6ES5 731-6AG00

1)

6ES5 731-6AG00

Notice

1. When connected in series, it is essential to connect the cable in the right direction (refer

to Figure 3-10).

2. The connecting cable is available for order only as a spare part. A description of the

connecting cables is provided in Chapter 7.

Adapter

Connecting cable

Active

Passive

6ES5 731-6AG00

6ES5 733-2xxx0

PG 7xx

PG 6XX

Figure 3-10

Direction of Connection: Adapter - Connecting Cable

Notice

When connecting the computing unit to another programming unit, switch the TTY
ports (COM 1) in one of the programming units by changing the jumper setting.
When the computing unit is delivered to you, this port is always set to active.