Technical Data

Release 04/02

A-3

Panel PC 670 Computing Unit, Equipment Manual

Environmental conditions

Temperature

operation

storage/transport

gradient

tested to DIN EN 60068-2-2:1994, DIN IEC 60068-2-1,
DIN IEC 60068-2-14,

+5

°

C to +45

°

C

- 20

°

C to +60

°

C

max 10

°

C/h (no condensation)

Relative humidity

operation

storage/transport

gradient

tested to DIN IEC 60068-2-3, DIN IEC 60068-2-30,
DIN IEC 60068-2-56

5% to 80% at 25

°

C (no condensation)

5% to 95% at 25

°

C (no condensation)

max 10

°

C/h (no condensation)

Mechanical environmental conditions

Vibration *)

operation

storage/transport

tested to DIN IEC 60068-2-6

10 to 58 Hz: 0.075 mm, 58 to 500 Hz: 9.8 m/s

2

5 to 9 Hz: 3,5 mm, 9 to 500 Hz: 9.8 m/s

2

Shock

operation

storage/transport

tested to DIN IEC 60068-2-29

50 m/s

2

, 30 ms,

250 m/s

2

, 6 ms,

Special Features

Quality assurance

to ISO 9001

Mainboard

Processor

Intel Pentium III / Celeron (see order documentation)

Internal processor cache

2x 16KB first level, 128/256/512 KB second level,
dependent on the processor used

Main memory

maximum 512 MB SDRAM,

memory configuration (see order documentation)

2. Level Cache

Processor internal

Free expansion slots

1 shared ISA/PCI (max 175 mm long),

1 PCI (max 265mm long)

max. permissible current input per ISA slot

max. permissible current input per PCI slot

in total (all slots)

5V 2A, 12V 0.3A, -12V 0.1A

5V 2A, 12V 0.3A, -12V 0.1A

5V 3A, 12V 0.6A, -12V 0.15A may not be exceeded

Drives

Floppy disk/LS240 drive

3.5” (1.44 MB) / 3.5” (240 MB, 120 MB or 1.44 MB)

Hard disk

3,5”, EIDE, UDMA33, hard disk capacity (see order
documentation)

CD-ROM-/CD-RW-/DVD(Combo) drive

650 MB / 4.7 GB

*) Restrictions for LS 240 with 120/240 MB data carrier and CD ROM /CD RW /DVD

10 to 58 Hz: 0.019 mm, 58 to 500 Hz: 2.5 m/s