I N S TA L L AT I O N

I N S T R U C T I O N S

C O N T R O L M O D U L E C O N N E C T I O N

Connect the RJ45 connector cable to the back
side of the remote-mounted control
module.

Connect the other end of the cable to the
electrical connection located on the right
side of downdraft assembly. Make sure that
all connections are tight.

Refer to the illustration placed on the front
of the downdraft for the correct orientation
of the RJ45 connector during installation
into the downdraft assembly.

C O N T R O L

M O D U L E

You will be required to drill three holes and
connect the control module to the downdraft
assembly using the cable provided. A 25 mm
diameter hole for the RJ45 connector cable will
be centered horizontally and vertically in the
back side of the control module. Two 6 mm
diameter holes for the mounting screws will be
located 51 mm from the center of the RJ45
connector cable hole, one on each side.

C O N T R O L M O D U L E I N S T A L L A T I O N

Mark the center of the control module on
the counter top. Measure 51 mm up (or left)
and 51 mm down (or right) to locate holes
for the mounting screws.

Carefully drill the three holes through the
countertop. Be careful not to damage or
chip the countertop surface while drilling.

Check the countertop thickness. Set the
control module in place and make sure the
threaded studs are long enough to allow
the nylon thumbnuts to fully engage.
Thicker countertops may require that the
holes be partially counter-sunk from below.

Apply a bead of caulk all the way around
the underside of the control module to
prevent liquids from reaching the electrical
connection or dripping through the holes in
the countertop. Position the control module.

From below the countertop, thread the two
nylon thumbnuts onto the studs of the
control module and hand tighten only.