I N S TA L L AT I O N

I N S T R U C T I O N S

bottom

flange

clamp

channel

nuts

sheet metal

screw

blower

cover plate

clamp

channel

nut

sheet metal

screw

blower

motor plug

Down blower discharge adjustment

Left or right blower discharge

A D J U S T I N G

B L O W E R D I S C H A R G E

D O W N D I S C H A R G E L E F T T O R I G H T

Adjusting the down discharge left to right will
keep the blower discharge in the down
position but allows some side-to-side adjust-
ment.

Follow these steps if the position of the blower
discharge needs to be moved left to right so
that ductwork does not interfere with floor
joists, plumbing or wiring below the unit. Refer
to the illustration below.

Place the downdraft assembly on its back
on a flat work surface.

Loosen the 4 nuts and 2 clamp channels.

Slide the blower to the desired position.

Use the supplied cover plate to close any
open space.

Tighten nuts to secure the top of blower
and use sheet metal screws through the
bottom flange to secure the bottom of the
blower.

D O W N T O L E F T O R R I G H T D I S C H A R G E

Substituting down discharge with left or right
discharge will switch the blower discharge
from the down position to the left or right of
downdraft assembly.

Follow these steps if it is necessary to rotate
the blower to the left or right discharge
location. Refer to the illustration below.

Place the downdraft assembly on its back
on a flat work surface.

Remove the 4 nuts and 2 clamp channels.

Remove the gear motor cover.

Carefully lift the blower and disconnect the
motor plug if necessary. Reposition the
blower and reconnect the motor plug.

Use the supplied cover plate to close any
open space.

Replace the clamp channels and use the
nuts to secure the blower in its new
position.

Reinstall the gear motor cover.

Use sheet metal screws (not supplied with
unit) through the bottom flange to secure
the bottom of the blower.

15