Sub-Zero Downdraft Ventilation User Manual

Page 8

Advertising
background image

I N S TA L L AT I O N

S P E C I F I C A T I O N S

Wolf downdraft Model ICBDD30 will fit most
762 mm wide cabinets, Model ICBDD36 will fit
most 914 mm wide cabinets and Model
ICBDD45 will fit most 1156 mm wide cabinets.
It is recommended that oversized cabinets be
used for easier installation. Cabinet backs may
need to be removed.

Wolf downdraft ventilation systems can be
mounted in an island, peninsula or standard
wall location.

The illustration below provides installation
dimensions for all Wolf downdraft models.
Pay careful attention to the areas of potential
interference as noted in the illustration.

IMPORTANT NOTE: To install a downdraft
system and a Wolf cooktop, you must allow for
a minimum 638 mm flat counter space from
front to back. A countertop with a raised lip or
backsplash may not allow enough space for
proper installation. 60 mm of flat countertop is
required behind the cooktop and 44 mm is
necessary between the back edge of the
cooktop and inside of cabinet back.

If downdraft Model ICBDD30 is installed in
combination with with two cooktops or inte-
grated modules, an integrated module support
(8603386) for downdraft ventilation is required.
The integrated module support is not required
for Model ICBDD45.

8

W O L F

D O W N D R A F T

V E N T I L A T I O N S Y S T E M S

54 mm

489 mm

COOKTOP CUT-OUT

DEPTH

914 mm

60 mm

638 mm

min

OF FLAT COUNTERTOP

*

8.7 mm

745 mm

COUNTERTOP

TO BOTTOM OF

AIR BOX

457

mm

92

mm

83 mm

127

mm

197 mm

16 mm

64 mm

min

WITH NO

RAISED LIP

*

*

AREAS OF POTENTIAL INTERFERENCE

610 mm

min

CABINET DEPTH

44 mm

min

BACK EDGE

OF COOKTOP
TO INSIDE OF

CABINET BACK

*

181 mm

Downdraft installation dimensions