Sub-Zero Downdraft Ventilation User Manual

Page 7

Advertising
background image

7

I N S TA L L AT I O N

I N S T R U C T I O N S

Models ICBDD45I and ICBDD45R

1156 mm

1048 mm

60 mm

230 mm

38 mm

DEPTH OF

DOWNDRAFT CHIMNEY

E L E C T R I C A L

R E Q U I R E M E N T S

Wolf downdraft ventilation systems require a
separate, 240 V 50/60 Hz power supply. The
service should have its own 10A circuit
breaker. The unit is supplied with a 2.5 m CEE
7/7 “Schuko” style Continental European
power cord. The specific location of the outlet
is not critical, as long as it is within reach of
the power cord that is located mid-way, top
and bottom, on the right side of the downdraft.

IMPORTANT NOTE: If Model ICBDD30 is to be
installed in a 762 mm wide cabinet, Model
ICBDD36 in a 914 mm wide cabinet or Model
ICBDD45 in a 1156 mm wide cabinet, the
electrical outlet cannot be located on the back
wall of the cabinet. The outlet can be placed in
an adjacent cabinet within reach of the power
cord. An access hole for the power cord must
be drilled in the cabinet wall.

Choose the electrical location shown in
the illustration below that best suits your
installation.

Location of electrical

914 mm

min

FOR MODEL ICBDD36

1156 mm

min

FOR MODEL ICBDD45

762 mm

min

FOR MODEL ICBDD30

OPTIONAL

ELECTRICAL

LOCATION IN

ADJACENT RIGHT

SIDE CABINET

E

O V E R A L L

D I M E N S I O N S

M O D E L S I C B D D 4 5 I A N D I C B D D 4 5 R

Overall Width

1156 mm

Width of Chimney

1048 mm

Overall Height (above countertop)

230 mm

Overall Depth

60 mm

Depth of Chimney

38 mm

Dimensions may vary to +

– 3 mm.

I M P O R T A N T
N O T E

You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.