6. Reinstall and bolt up the jacket halves.
The fuse for the Fireman’s Switch is a 1.25 amp 1-1/4x1/4”
fast blow fuse, available locally.

MAXIMUM TEMPERATURE SET POINT

1. Unbolt and remove upper jacket halves (see Figure 3,

Page 5).

2. Depress clips and remove control panel board dome

(see Figure 9, Page 10).

3. Push the Max. Temp. Set Point button on the back of

the control board (see Figure 26). The following
sequence should happen:

A. The unit will come on and the POOL ON light will

come on.

B. Press the

▼Temp or ▲Temp pad (on TOP of the

panel) to set maximum pool temperature.

C. Wait 30 seconds; the POOL ON light will go off and

the SPA ON light will come on.

D. Press the

▼Temp or ▲Temp pad (on TOP of the

panel) to set maximum spa temperature (set temper-
ature to 104°F (40°C) or less).

E. Wait 30 seconds; the SPA ON light will go off and

the unit will shut down.

4. Reinstall and bolt up the jacket halves.