3.2 Adjustment for LPG

Loosen screw A and push air regulator B to
the bottom. With a 7 mm wrench, remove
nozzle C and replace it with the proper one
(follow the instructions on the reference
tables for the type of gas to be used). The
torque wrench setting of the nozzle must not
exceed 3 Nm. Adjust the air by sliding
regulator B until reaching distance “X
shown in the table in paragraph “3.4
Regulation of primary air”. Lock regulator B
by tightening screw A.

Model CSA19

Models CSA196 / CSA20

LPG – 2.75 kPa

LPG – 2.75 kPa




Burner

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Auxiliary

4.80

1.5

0.60

5.30

1.5

0.62

Semi rapid

5.80

1.5

0.67

6.60

1.5

0.70

Rapid

9.30

3.2

0.85

9.00

3.2

0.82

Wok

13.00

5.4

1.00

15.00

5.4

1.05

Fish burner (*)

9.20

3.2

0.85

6.60

2.9

0.70

(*) Models CSA19 / CSA196

3.3 Adjustment for natural gas

The hob has been tested for natural gas at a pressure of 1.0kPa. To
allow the unit to work with this type of gas, perform the same operations
described in paragraph “3.2 Adjustment for LPG”, but choose the nozzles
and adjust the primary air for natural gas, as shown in the following table
and in paragraph “3.4 Regulation of primary air”.

Model CSA19

Models CSA196 / CSA20

NG – 1.00 kPa

NG 1.00 kPa




Burner

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Nominal gas

consumption

(MJ/h)

Turn-down gas

consumption

(MJ/h)

Injector

(mm)

Auxiliary

5.30

1.4

1.04

5.30

1.4

1.00

Semi rapid

6.60

1.4

1.15

6.60

1.4

1.15

Rapid

9.00

2.4

1.35

9.00

2.4

1.35

Wok

12.50

4.3

1.65

15.00

4.3

1.75

Fish burner (*)

10.20

3.2

1.45

6.60

2.9

1.15

(*) Models CSA19 / CSA196